Reducing gear with centre return spring, 85 degrees
3 phase 125A fuse holder
3 phase 50A fuse holder
14 x 51 32A GG fuse
22 x 58 63A GG fuse
Switching regulator 15V 15W RS 15-15
Fuse 3.15 Amp
Inter card cable
FastPAD 2 max power assembly
VISIOPAD screen card
LED strip
FastPAD 2 Mini relay connection
VISIOPAD coder
FastPAD 2 Max UL relay connection
Safety box 577DBC
Motorised valve 3/4 230V 50/60 Hz female
Inlet/outlet 1 way solenoid valve, 10 L/min
Pump kit
CP2A pump
FHKUC flow meter
10.2 x 15 diameter 2 mm thick metal-asbestos plastic gasket
Heating element + immersion heater gasket
Door stop
3B-390977NU – 10/18
Synthetic filter
These appliances are for professional use, only appropriately trained personnel should use them.
¨
¨
These appliances are intended to be used for commercial applications, for example in kitchens of restaurants, canteens, hospitals and in
commercial enterprises such as bakeries, butcheries, etc., but not for continuous mass production of food.
¨
These appliances must be installed with sufficient ventilation to prevent the formation of an excessive concentration of substances harmful for
health within the premises in which they are installed.
The rate of new air required for combustion is 2m3/h per kW of heating power.
¨
¨
Never block the condensate exhaust flue, because the pressure could rise in the appliance and pose a risk of explosion.
If an error message appears consult the list of error messages and follow the ADVICE given
¨
When cleaning high pressure jets or lances should never be used.
¨
NEVER start the oven WITHOUT HAVING POSITIONED AND LOCKED the ventilation duct.
¨
Do not remove the ventilation duct and the drain grid located in the oven. If this grid is missing do not start the oven.
¨
Always use a qualified technician to install the equipment and if necessary change the oven from one gas to another.
¨
IMPORTANT: Please be aware that when cooking dishes prepared with alcohol (coq au vin, pears in wine, etc....). Vapour saturated with
¨
alcohol may when heated cause an explosion in the oven and due to the sealed door, create a momentary overpressure which may cause an
irreversible deformation of the panels. This risk is further increased when the user adds alcohol to the products near the end of the cooking cycle
and closes the door to complete cooking.
¨
The appliance must be isolated electrically during cleaning or maintenance and when replacing parts.
¨
For long term reliability and safety it is advisable to have the unit serviced by suitably qualified technicians
inspection and cleaning of venturis, cleaning jets, adjustment of air rings, cleaning vents, checking for possible leaks, checking control elements,
regulating and safety accessories...).
The oven must be meticulously maintained on a DAILY basis (see the "Maintenance" chapter). In particular, the fans, heating elements
¨
and internal surfaces must be kept clean grease and mineral deposits must not be allowed to accumulate.
¨
Preheating (20 level ovens): Whatever the cooking mode, these ovens are designed to be preheated with the trolley in place. See «practical use
advice ».
¨
Using a trolley or preheating plate (optional) is compulsory for automatic cleaning of 20 level ovens.
¨
Never place the probe behind the ventilation duct (the probe may deteriorate in proximity to the elements or gas exchange.
¨
NEVER APPLY ANY CLEANING PRODUCT WHEN THE OVEN IS HOT, AT ANYTHING OVER 60°C THE SURFACE WILL BE
IRREPARABLY DAMAGED.
Do not open the oven door during a cleaning cycle.
¨
Combination ovens should be cleaned with specific products which can resist temperature of up to 70°C. An inappropriate cleaning or descaling
¨
product may have a slightly corrosive effect.
The detergent chemical risk should not exceed 3 in accordance with EN 1717 (Toxicological information FDS: LD50 > 200mg/kg).
¨
We strongly recommend the use of cleaning products supplied by the manufacturer to ensure good results and optimize the service
¨
life of its components.
Except for the UK market: No detergent product is recommended or supplied. Any detergent used with this appliance must have been verified to
represent no greater risk than Fluid Category 3. If the detergent used represents a Fluid Category risk greater than Fluid Category 3 alternative
backflow protection to the double check valve supplied with the appliance will be required immediately upstream of the appliance. The backflow
protection used must be appropriate to the risk posed by the detergent.
In order to ensure optimum cleaning results without the risk of chemical attack we recommend using our cleaning chemical BK101. Other
¨
products can be used. Generally cleaning products that are compatible with our ovens should:
- have a composition based on potassium hydroxide with a concentration < 25%, WITHOUT sodium hydroxide
- be suitable for use at a temperature of 60°C.
- include anticorrosion agents
For maximum efficiency of the descaling product without damaging the material and components of the oven, you should use an appropriate
¨
descaler. The use of certain acids has an irreversible destructive effect that may cause significant damage. The descaling product must contain
305108
307468
307469
307471
307472
308350
309407
309581
309635
309636
309638
309641
309644
309663
310324
314359
314362
314367
314379
314381
318033
366461
366572
Page 14
386087
19 RECOMMENDATIONS
Drain grid
- 13 -
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
-
x
x
x
x
-
x
x
x
BONNET GRANDE CUISINE
Rue des Frères Lumière - Z.I Mitry Compans
77292 MITRY MORY Cedex
x
x
x
x
x
x
x
x
x
x
x
-
x
x
x
x
x
x
x
x
x
x
EN
x
x
(Dismantling of burners,