ERROR CODES – Top Mount Control Board
Error messages will appear and scroll across the display of the control board if the unit experiences an
abnormal condition. When these errors occur, the unit will proceed to a shutdown cycle, during which
time the control board will not permit the unit to be restarted. At the end of the shutdown cycle, the
control board will allow the code to be cleared and/or the unit to be restarted. In the event an error
message appears, however, it is recommended to refer to the troubleshooting section of the manual
(or call Tech. Support if needed), to determine and correct the underlying cause of the message's
appearance.
NOTE: See next section for information on Troubleshooting the Error Codes
Failed to start
If the unit does not reach its minimum operating (or "Proof of Fire") temperature by the
end of the allotted startup time, the control board display will scroll "FAILED TO START
SHUTTING DOWN", at which time the unit will initiate a shutdown cycle. The message will
continue to scroll during this time until the unit shuts completely off. During this time, the
stove cannot be restarted; if the "ON" button is pressed during this shutdown, the unit will
scroll "STOVE MUST SHUT DOWN TO CLEAR ERROR" once, before reverting to the previous
message.
Once the unit has shut down completely, the display will continue to scroll "FAILED TO
START". At this point the stove can be restarted in its normal sequence by pressing the
"ON" button, or the code can be cleared by pressing the "OFF" button.
Failed on Over Temp
If, at any time while the unit is in operation and the firebox sensor reads too high of a
temperature, the unit will display the following message: "FAILED ON OVER TEMP
SHUTTING DOWN". The unit will then initiate a shutdown cycle, and the message will
continue to scroll during this time until the unit shuts completely off. During this shutdown,
the stove cannot be restarted; if the "ON" button is pressed during shutdown the unit will
scroll "STOVE MUST SHUT DOWN TO CLEAR ERROR" once, before reverting to the previous
message.
Once the unit has shut down completely, the display will scroll "FAILED ON OVER TEMP". At
this point the stove can be restarted in its normal sequence by pressing the "ON" button, or
the code can be cleared by pressing the "OFF" button.
Vacuum Loss
This unit is equipped with a vacuum actuated "Door Ajar" safety switch. If this switch is
sensed as being open for a period of 30 continuous seconds, the control board will scroll
IMPORTANT! READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING CLEANING THE UNIT AS SPECIFIED, AND
ENGLAND'S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT, OR DUE TO UNSAFE INSTALLATION OR
REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED.
USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH ANY QUESTIONS.
23