Resetting the bypass valve

13
14
1. Stop the filtration
pump and remove
the bypass valve
from the vacuum
point or skimmer
(photo 13) .
2. Disconnect
VICTOR's hose
from the valve
(photo 14).
33/56
15
16
2008/05- Indice de révision : B - code : 0030010
3. Holding the valve
above the basket
with one hand,
rotate the inner
section of the valve
1/4 turn (photo 15 )
until the internal
section pops into its
"set" position (photo
16) .
4. Reconnect the
hose and insert the
bypass valve with
valve cone back
into the vacuum
point or skimmer
(photo 13) .