Problem: VICTOR is climbing out of the pool
CAUSE
Suction pressure is too high
Problem: The filtration pump is very loud when VICTOR is connected
CAUSE
Pump is cavitating (not enough water in the
pump).
Problem: Right wheel will not turn by hand
CAUSE
The turbine vanes are clogged/jammed
Gears, drive shafts, and/or wheel gears may
be clogged/jammed
SOLUTION
- Install a bypass valve
- To reduce the water flow (and hence suction
pressure) through VICTOR, adjust flow
rates between VICTOR suction (vacuum
point or skimmer) and other suction points
(main drain or skimmer).
If this is not possible, decrease pump
horsepower or install a discharge valve
between pump suction and the filtered water
outlet to meet VICTOR's requirements.
SOLUTION
Open the main drain or skimmer valve wider
to provide an adequate flow to the pump.
If this is not possible, decrease pump
horsepower or install a discharge valve
between pump suction and the filtered water
outlet to prevent cavitation.
SOLUTION
Remove debris from the vanes
Remove debris from the gears, drive shafts
and/or wheel gears