Automatic Function; Dry Run Protection; Water Leakage - SPIDO SPRING 1300AUTO Notice D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

[Getting started]

Automatic function

DRY RUN PROTECTION

When running, in case of dry run for 20s, the LED (1A) is
flashing during 40s. Then pump stops 5s, and repeat this
cycle 4 times.
After 4 cycles, LED (1B) is lightened and pump safety stop
is activated.
Pump can be restarted once by pressing on the switch (1).
After this start, if default is still there, the pump will stop
running, and it will be necessary to unplug it from the mains
to restart it again.
OUTPUT CLOSED
When running, in case of dry run for 20s, the LED (1A) is
flashing during 40s. Then pump stops 5s, and repeat this
cycle 4 times.
After 4 cycles, LED (1B) is lightened and pump safety stop
is activated.
Pump can be restarted once by pressing on the switch (1).
After this start, if default is still there, the pump will stop
running, and it will be necessary to unplug it from the mains
to restart it again.

WATER LEAKAGE

In case of water leakage, the pump will start and stop
frequently. This situation can cause damages to the pump.
In order to avoid this risk, pump has been designed to detect
water delivery < 100l/h (around 6 starts in 100 seconds). In
that case, defect is detected, LED (1B) is lightened
In that situation, it will be necessary to unplug the pump from
the mains to restart it again.
.
.
6

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

002172

Table des Matières