Service and Maintenance
Do not allow the machine and fluid to become contaminated.
․
Regularly fill distilled water to fluid tank and run the machine to clean the system.
․
After cleaning, refill Antari fog fluids into fluid tank and make sure the machine can
produce fog properly.
It is recommended to run the machine on a monthly basis in order to achieve best
․
Step. 6
The red-framed area is where the W-DMX
board is placed.
Step 7. Install the W-DMX onto the main PCB and
then screw the screw tightly. The installation of W-
DMX antenna and W-DMX board is completed.
The Part Number of Optional Wireless DMX
module is W-DMX-PCBR (1 x W-DMX antenna + 1 x
W-DMX board)
16
Step 5.
Connect the antenna (Part #
W-DMXR onto the W-DMX
board (Part # W-DMX-PCB)