14
Electric installation of the control panel
Illustration
Use the following illustration in connection with the procedure described below:
Procedure
Follow these guidelines for the installation of the green control lamp and the rotary
knob/switch. Use the illustration as support:
NB: All cables are led into cable trays to keep them in order!
Contactor front plate
Trin
1
Cut the foil from the small hole on the contactor front plate and press the
green control lamp through the hole from the front. When it clicks, the lamp
is correctly placed
2
Release the tap on the green lamp in the middle and fit it onto the new
control lamp
3
Fit the black wire with tap onto the lamp
4
Connect the other end of the black wire to terminal 10 of the terminal strip on
the PCB
5
Cut the foil from the large hole of the contactor front plate and press the
switch through. Fasten the switch by the screw
6
Connect the 2 brown wires to terminals 3 and 4 of the switch
7
Connect the other end of the two brown wires to terminals 39 and 40 of the
terminal strip on the PCB
8
Finish by re-fixing the 3 front plates to the dehumidifier
Handling