Dantherm Elvarmeunit Guide D'installation page 12

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

12
Mounting of the electric heating unit
Illustration
Use the following illustration in connection with the procedure described below:
Procedure
Follow these guidelines when mounting the electric heating panel:
Step
1
Switch off all power to the dehumidifier
2
Dismantle the external top plate by unscrewing the 6 torx screws
3
Lift off the internal top plate (see illustration in the section "General
information")
4
Place the electric heating unit on the intermediate plate, that can be seen
when the top plates have been dismantled, and fix it by the 4 torx screws..
The side where the cables are must turn out against the front with the control
panel of the CDS.
5
Release the 2 wires by cutting the strips and take them through the punched
holes of the intermediate plate and onto the control panel. (see illustration
above)
6
Remount the internal and external top plates.
You are now ready to install the electric heating unit. This is described in the
following section
Holes for cables
Action