12
Mounting of the electric heating unit
Illustration
Use the following illustration in connection with the procedure described below:
Procedure
Follow these guidelines when mounting the electric heating panel:
Step
1
Switch off all power to the dehumidifier
2
Dismantle the external top plate by unscrewing the 6 torx screws
3
Lift off the internal top plate (see illustration in the section "General
information")
4
Place the electric heating unit on the intermediate plate, that can be seen
when the top plates have been dismantled, and fix it by the 4 torx screws..
The side where the cables are must turn out against the front with the control
panel of the CDS.
5
Release the 2 wires by cutting the strips and take them through the punched
holes of the intermediate plate and onto the control panel. (see illustration
above)
6
Remount the internal and external top plates.
You are now ready to install the electric heating unit. This is described in the
following section
Holes for cables
Action