3-6. Weld Output Terminals And Selecting Cable Sizes

YTurn Off power before
connecting to weld output
terminals.
*Weld cable size (AWG) is based on either a 4 volts or less drop or a current density of at least 300 circular mils per ampere. Contact your distributor for
2
the mm
equivalent weld cable sizes.

3-7. Connecting Weld Output Cables

Tools Needed:
3/4 in (19 mm)
Y Turn off power before connecting to
weld output terminals.
Y Failure to properly connect weld
cables may cause excessive heat
and start a fire, or damage your ma-
chine.
OM-225 757 Page 12
Total Cable (Copper) Length In Weld Circuit Not Exceeding
100 ft (30 m) Or Less
10 − 60%
Welding
60 − 100%
Duty
Amperes
Duty Cycle
Cycle
100
4
150
3
200
3
250
2
300
1
350
1/0
400
1/0
500
2/0
4
1
Do not place
anything between
weld cable terminal
and copper bar.
2
3
Correct Installation
1
Weld Output Terminal
2
Supplied Weld Output Terminal Nut
3
Weld Cable Terminal
4
Copper Bar
Remove supplied nut from weld output ter-
150 ft
200 ft
(45 m)
(60 m)
4
4
3
3
2
1
2
1
1/0
1
1/0
2/0
1/0
2/0
3/0
2/0
3/0
4/0
2/0
3/0
4/0
3/0
4/0
2-2/0
250 ft
300 ft
350 ft
(70 m)
(90 m)
(105 m)
10 − 100% Duty Cycle
2
1
1/0
1/0
2/0
3/0
2/0
3/0
4/0
3/0
4/0
2-2/0
4/0
2-2/0
2-3/0
2-2/0
2-3/0
2-3/0
2-2/0
2-3/0
2-4/0
2-3/0
2-4/0
3-3/0
Incorrect Installation
minal. Slide weld cable terminal onto weld
output terminal and secure with nut so that
weld cable terminal is tight against copper
bar. Do not place anything between weld
cable terminal and copper bar. Make
sure that the surfaces of the weld cable
terminal and copper bar are clean.
400 ft
(120 m)
1/0
3/0
4/0
2-2/0
2-3/0
2-4/0
2-4/0
3-3/0
S-0007-E
803 778-A