h
MODEL
GHT
[mm]
[kg]
iv8
400
8
iv12
500
10
iv16
600
12,5
iv20
900
19

TECHNICAL DATA

• Flow Rate
• Minimum/Maximum Pressure
• Feed Water Min./Max. Temperature 4°C ÷ 25°C
This leaflet is an integral part of the product.
Please read the warnings provided carefully as
these provide important information concerning
the safe installation, use and servicing of this pro­
duct. This water softener is intended to be used to
soften cold drinking water only, any other use is
considered improper and as such unreasonable.
WARNING: use only sodium chloride NaCl in lar­
ge grains (kitchen salt) for regeneration. The use
of any other chemical substances or products is
strictly forbidden.
The resins in the water softener are needed
for this to work properly: please do not throw
them away.
INSTALLATION
• After removing the packaging, make sure that
the water softener isn't damaged. Keep the
packaging materials (plastic bags, cardboard
box etc. ...) out of the reach of children as they
can be dangerous. The water softener should be
installed in full observance of the current laws,
following the manufacturer's instructions and by
experts. If installed incorrectly, the equipment
may cause injuries to people and animals and
damage to property, in which case the manu­
facturer cannot be held liable.
• Install the water softener in rooms where the
temperature is minimum 5°C and maximum
30°C (Centigrade).
CONNECTION TO THE WATER MAINS (figure
1)
• The user must install a tap between the water
mains and the water softener so that the water
can be turned off in an emergency, plus a check
valve to avoid any pressure returns.
• Connect the water inlet and outlet hoses to the
provided unions and make sure they are tighte­
ned properly.
• Place the hose in the joint and push it until it
stops. The metal elements of the quick con­
nection prevent the hose from coming out.
Instruction leaflet and warnings for water softeners
LITERS OF WATER SOFTENED DEPENDING ON HARDNESS
RESINS
SALT/REG.
[l]
[kg]
200 ppm CaCO
5,6
1
1680
8,4
1,5
2520
11,2
2
3360
14
2,5
4200
900 l/h
1 ÷ 8 bar
20°f
30°f
11°d
16°d
300 ppm CaCO
400 ppm CaCO
3
3
1120
1680
2240
2800
To disconnect the water softener, press the pro­
truding pincers and at the same time extract the
hose from the quick connection.
Place the drain hose directly in a drain.
COMMISSIONING
• RINSING OF RESINS
Turn the valve knob to position 4, back wash.
Open the water inlet and let the water flow until
it is clear.
Turn the knob back to position 1.
• ROUTINE REGENERATION
• position 2
1) Turn the valve knob to position 2. Loosen the
cover knob and wait for the pressure to drop.
2) Remove the cover and add the salt in the
amount indicated to suit the model (see table
1).
3) Return the cover and tighten the knob securely.
WARNING: Remove any salt from the seal on the
cover and the top of the water softener.
• position 3
4) Turn the valve knob to position 3.
5) Let the salty water flow from the drain hose un­
til the water is soft (about 40 minutes).
• position 4
6) Turn the valve knob to position 4, wait about
30 seconds (the water softener does not supply
any water during the back wash).
• position 1
Turn the valve knob back to position 1, opera­
tion mode.
WARNING: during the regeneration equip-
ment connected to the softener is supplied
with water but not softened.
To ensure the efficiency of the water softener at all
times, we recommend routine regeneration to suit
the use made of the water softener and the hard­
ness of the water used.
Please use the sheet printed on the last page to
keep a note of the dates when regeneration is
carried out.
Water Softener iv
40°f
50°f
22°d
28°d
500 ppm CaCO
600 ppm CaCO
3
3
840
672
1260
1008
1680
1344
2100
1680
60°f
33°d
3
560
840
1120
1400
3

Hide quick links:

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Iv12Iv16Iv20Iv sérieIv serie

Table des Matières