Maintenance, care and testing:
Before each use, the user must check the system for integrity (see safety instructions).
The owner/operator is obligated to ensure that the anchor device is in perfect and flawless
condition at all times. It is therefore recommended, as needed, but at least every 12
months (e.g., within the general roof maintenance), to have the anchor device inspected
*)
by one of ST QUADRAT Fall Protection S.A. trained and certified experts.
This regular inspection/monitoring is essential, as the safety of the user depends on the
effectiveness and durability of the anchor device.
The check list in the annex can be used to aid the inspection process.
Test loading the system for the purpose of verification is not allowed on the structure!
An inspection log card is included in the appendix of these user instructions, on which the
inspection by the competent person can be documented.
The date of the next scheduled inspection must always be entered on the system
information sign and on the inspection log card.
Prevent contact between the stainless steel anchor device and "black" steel (including in
the form of grinding dust), as well as chemicals and other aggressive substances since
this can lead to corrosion.
®
The anchor device
LUX-top
FSE 2003
is permanently weatherproof.
Depending on the use conditions, the anchor device must be cleaned occasionally with hot
water.
Never use aggressive cleaning products or chemicals!
Miscellaneous:
Changes or additions to the anchor device may only be made with the prior written
consent of the manufacturer. Equally, all repairs may only be carried out in agreement
with the manufacturer.
If resold to another country, for purposes of user safety, the reseller must provide
instructions for use, maintenance, periodic inspections and repairs in the language of the
respective country.
*)
Note: According to the German DGUV regulation 112-198 before anchor devices, which are permanently mounted on a
building or structure can be used, it must be ensured that the last professional inspection is not older than one year, if sh orter
inspection intervals are not specified due to the prevailing operating conditions.
ST QUADRAT Fall Protection S.A.