The stability of the mounting base after a person secured to the
falls, must be checked by a qualified person before re-assembling a new anchor device
on site. If necessary, the complete lifeline system including the anchoring system or
individual components must be replaced.
On-site operating instructions with information on the location and use of the anchor
devices should be attached at the access to the safety system (e.g. roof hatch)!
The relevant national regulations and the health & safety regulations (in Germany the
accident prevention regulations of the trade associations responsible for industrial
safety) and any other relevant regulations must be complied with when using the
®
LUX-top
FSE 2003
 TRBS 2121 "Technical rules for health & safety at work - risk to people due to falling".
 DIN 4426 "Safety requirements for workplaces and transport routes".
 DIN 363 "Personal fall protection equipment - personal fall protection systems".
 DGUV Regulation 38
 DGUV Regulation 112-198 "Use of personal protective equipment against falls"
 DGUV Information 201-008
 DGUV Regulation 101-016 "Roof Work"
 DGUVI 201-056 "Planning principles of anchor devices on roofs"
 ASR A2.1
"Technical rule for workplaces - Protection against falling and falling objects,
entering dangerous areas"
Ensure safe and stable position when using the anchor device!
There must be a rescue plan which takes into consideration all possible emergencies
so that potential rescue operations can be carried out quickly and safely.
The lanyard must always be set as short as possible, even when fall arrest systems
are used, in order to reduce any free-fall height in case of a fall to a minimum. It is
essential for safety that the position of the anchor device and the plan of work be
chosen so that any free fall and the fall height are limited to a minimum. Ideally, a
fall over the edge should be completely prevented by appropriate use of the
PFPE against falls from a height.
Position the anchor device on the building so that in case of a fall over the roof edge,
the maximum possible fall factor is 1.
Please note that failing to follow these user instructions, and if the documentation is
incomplete, all claims for compensation are excluded.
The manufacturer must be contacted in case of any uncertainty during installation or
use of the system!
ST QUADRAT Fall Protection S.A.
system. For Germany these include, among other things:
"Construction Work"
"Roof Work"