Use of the system for purposes other than those for which it is intended, e.g. hanging
loads or transporting materials is not allowed.
The anchor device may only be used for securing persons against falls by attaching the
PFPE (personal fall protection equipment) according to EN 363, consisting, for example
of a full body harness (EN 361), lanyard (EN 354) and energy absorber (EN 355).
If the anchor device is used as part of a fall arrest system the user must be equipped
with an energy absorber, which limits the maximum dynamic forces that act on the
user during an arrest to 6 kN maximum.
The use of the anchor device in combination with retractable fall arresters according to
DIN EN 360 and guided type fall arresters on a flexible anchorage line (DIN EN 353-2)
is possible but only with models approved by the manufacture. Alternatively,
appropriate measures must be taken to ensure that the assembled combination can
only be used as a restraint system, to prevent the fall from actually happening.
The combination of individual elements of the above-mentioned equipment with the
®
LUX-top
FSE 2003
proper functioning of one of the elements. Therefore, always ensure that the
equipment parts put together to form a system are compatible with each other.
The components of the personal protective equipment against falls from a height must
be checked to ensure that they are in proper condition and that they comply with
these user instructions.
Attachment to the
steel cable with the connector of the PFPE (carabiner according to DIN EN 362), in
accordance with their instructions for use. For systems with freely traversable
intermediate brackets, the connector of the PFPE is inserted into the carabiner of the
cable glider
LUX-top
®
In the
LUX-top
safety of the user that he only transfers the connecting element of the PFPE to the
non-traversable intermediate bracket when there is no risk of falling.
The user must visually inspect the integrity of the anchor device before each use to
ensure its proper functional and maintained condition.
®
The
LUX-top
FSE 2003
inspection by qualified personnel (with written documentation) if there are safety
concerns regarding its condition (e.g. heavy corrosion, deformations, lightning strikes,
damaged system components, loose parts, poor quality of the mounting base) or after
mechanical stress following a fall incident.
ST QUADRAT Fall Protection S.A.
system may increase the potential of fatal risks by impairing the
®
LUX-top
FSE 2003
®
SG.
FSE 2003 system
system should no longer be used and subject to an
Your competent partner for fall protection
Page 3 Version 04/2017
system takes place directly on the stainless
non-traversable
it is essential to ensure the
www.lux-top-absturzsicherungen.de

Publicité

Table des Matières
loading

Table des Matières