7.6 Electrical system connections lift without mechanical safety
•
Connect magnetic proximity pickups of both the platforms to the control desk following
the numbering indicated on the cables;
•
Connect the external power supply to the positions indicated in electric diagram;
•
Ensure that the lift is suitably grounded.
1= High Limit
2= Down Limit RIGHT;
3= Down Limit LEFT;
7.6.1 Electrical system connections lift with mechanical safety
• Connect the cables of the two runway potentiometers to the control unit, connecting
the cables to the correct connectors as follows;
connect the cable marked 1(R) to connector SK12 of the electronic board
114
devices fig.18
devices fig.18_1
(1)
High Limit
4. Power (+) (Brown)
5. Negative (-) (Blue)
14. Signal (Black)
(2)
Down Limit RIGHT
7. Power (+) (Brown)
8. Negative (-) (Blue)
9. Signal (Black)
(3)
Down Limit LEFT
1. Power (+) (Brown)
2. Negative (-) (Blue)
3. Signal (Black)
Operator's m anual
18