TABLE FOR THE CHOICE OF THE INJECTORS
A
BURNERS
Auxiliary (A)
Semirapid (SR)
Rapid (R1)
Fish burner
Oven (thermostat) - mod. Z 8050G
Oven (thermostat) - mod. Z 9050G
Grill - mod. Z 8050G
Grill - mod. Z 9050G
BURNERS
Auxiliary (A)
Semirapid (SR)
Rapid (R1)
Fish burner
Oven (thermostat)
mod. Z 8050G
Oven (thermostat)
mod. Z 9050G
Grill
mod. Z 8050G
Grill
mod. Z 9050G
*
= Value of reference
38
IR VENT NECESSARY FOR GAS COMBUSTION
Nominal
Reduced
power
power
By-
[kW]
[kW]
pass
1,00
0,30
27
1,90
0,38
29
3,15
0,60
39
3,50
0,85
47
5,00
1,10
53
6,20
1,30
58
4,00
-
-
4,60
-
-
Air vent necessary [m
2
3,8
6,3
7,1
10
12,4
8
9,3
G30/G31
28-30/37 mbar
Ø injector
Ring opening
[1/100 mm]
[mm]
50
3 *
67
5,7 *
86
Fully open *
92
Fully open *
107
Fully open *
120
Fully open *
98
Fully open *
107
Fully open *
=
3
(2 m
/h x kW)
3
]
Cat:
G20
20 mbar
Ø injector
By-
[1/100 mm]
pass
72
100
130
135
160
180
150
165
II
2H3+
Ring opening
[mm]
1 *
2 *
5 *
5 *
1,5 *
1,5 *
3 *
3 *