Electrical Connection - Bartscher NT 501 Mode D'emploi

Masquer les pouces Voir aussi pour NT 501:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 49

5.1.3 Electrical connection

DANGER! Risk of electrical shock!
The device may cause injuries if installed improperly!
Before installation the local power grid specification should
be compared with that of the device (see rating plate).
Connect the device only in case of full compliance!
Before connecting the device to the power supply, make sure that the values of
voltage and frequency shown on the rating plate are consistent with the data of the
existing electrical installation.
Voltage tolerance shall not exceed ± 10%.
If the device is placed on the base with wheels that make it easy to move the device,
it is recommended to connect it to the power supply first and then install the pizza
oven at the site of operation.
When moving the device, make sure that the power cord is not damaged.
The power cord should be placed in such a way as to ensure that in no place it is
exposed to the temperature exceeding 50 ° C.
Electrical circuit must have at least 25A protection.
Recommended socket: CEE32A/400 V
Equipotential bonding connection
Equipotential bonding conductor between different devices shall be connected to the
terminal marked with
This terminal allows for connecting the equipotential bonding conductor (yellow-green
colour) with a cross section from 4 to 10 mm
The device must be connected to the equipotential bonding circuit the effectiveness
of which complies with the instructions included in the valid regulations.
. The terminal is located at the rear side of the device.
2
.
- 37 -