Setting The Maximum Current; Setting The Network Configuration - Porsche Wall Charger Connect Mode D'emploi Et Instructions D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

b The connection cables used have the correct
cable diameter: terminals for L1 and L2/N cables
are designed for AWG 0 to AWG 4. Terminal for
ground is designed for cables up to AWG 6.
b Three cables are required for connection.
1. Introduce the cables into the Wall Charger
Connect. Observe the minimum bending radii
of the cables.
2. Connect L1 (1) and L2/N (2) to the large black
terminal block.
Tighten the screws of the terminal block with
a torque of 3 ftlb. (4 Nm).
3. Connect the ground (3) to the small terminal
block. Tighten the screw of the terminal block
with a torque of 1.5 ftlb. (2 Nm).
Fig. 14: Cable connection points
Setting the maximum current and the network
configuration
Electric shock
DANGER
Changes to the settings are not evaluated by the
device when it is switched on. There is also the risk of
receiving an electric shock.
e Switch off the supply voltage and make sure that
the voltage is off before installation works are
performed.
e Before the Wall Charger Connect is connected,
check which network configuration is available on
site. The Wall Charger Connect may only be used
with the network configurations listed here in the
corresponding arrangements. If you are unsure
about the network configuration, consult a
qualified electrician.
e The fuse for the device must be switched off
while the settings are made for the network
configuration and maximum current.
The maximum current and the network configuration
are each set via a separate switch.
Installation Instructions
Fig. 15: Rotary and DIP switch
1
I Sel rotary switch (I Selection = Pre-selection of
maximum current)
2
Net DIP switch (Network = Selection of power supply
network configuration)
Setting the maximum current (I Sel)
The maximum current of the Wall Charger Connect
can be limited via the I Sel rotary switch. This is
installed next to the terminals.
e Use a small screwdriver to set the maximum
current.
Switch position
Current value
F
80
E
63
D
48
C
40
B
32
A
24
9
20
US
FC
ESM
19