Closing the cover
Before switching on the Wall Charger Connect, the
cover must be secured using the enclosed screws.
b Use Torx TX 25 screws.
e Tighten the 13 screws to secure the cover with
a tightening torque of 3.3 ftlb. (4.5 Nm).
Fig. 16: Screw points of the cover
Attaching the decorative front panel
The decorative front panel is secured via four screws.
The screwholes are in the recess for winding the
cable (not visible from the front).
e Position the decorative front panel on the device
and fix with the four screws (tightening torque
3.0 ftlb. (4 Nm)).
To do this, use a Torx TX 25 screwdriver
with a short shaft.
Fig. 17: Screw attachment points in the recess for winding
the cable (rear view of the Wall Charger Connect)
Putting the Device into Operation
e Switch on the charger by pressing the Power
button.
In the display, the control panel for the further
setup of the device appears.
f Please see chapter "Operating Instructions" on
page 7.
Installation Instructions
Technical Data
Electrical data
9J1.068.209
Power
19.2 kW
Rated current
80 A
Rated voltage
120/208-
240 V AC, 120 V to
ground
Phases
1/2
Power supply frequency
50 Hz/60 Hz
Overvoltage category
II
(IEC 60664)
Integrated residual current
Type A (AC: 20 mA)
device
+ DC: 56 mA
Protection class
I
Degree of protection
Enclosure 3R (IP55)
Transmission frequency
2.4 GHz, 5 GHz
bands
Transmission power
20 dBm
Mechanical data
Weight
29 lbs. (13 kg)
Vehicle cable length
14.8 ft (4.5 m)
Ambient and storage conditions
Ambient temperature
–22 °F to +122 °F
(–30 °C to +50 °C)
Humidity
5%–95% non-
condensing
Elevation
max. 13,123 ft.
(4,000 m) above
sea level
US
FC
ESM
21