Installation Instructions
3. Use a saw or a sharp knife to make the
US
breakthrough for the cable conduit.
The outer cover of the Wall Charger Connect has
markings at the top and bottom for 1 ¼ and
FC
¾ inch cable conduits.
ESM
Breakthrough area
at top
4. In the breakthrough area, the opening for the
cable conduit fitting can be cut out using a
holesaw.
The flat area has a point in the middle to centre
the holesaw.
Use a holesaw that has the same diameter as
the cable conduit to be used.
Fig. 12: Centering to position the holesaw
18
5. Install the cable conduit fitting in the
Wall Charger Connect.
Make sure that the cable conduit is watertight
when installed.
6. Guide the cable through the cable conduit into
the interior of the Wall Charger Connect.
7. Next seal the opening with duct seal.
When doing so make sure that the cable conduit
is completely sealed with the duct seal.
Only use UL-certified duct seal of category
R 14721.
Wall installation
The Wall Charger Connect has four screw
Breakthrough area
connections in total for installation on the wall.
at bottom
Fig. 13: Wall fastening openings on the Wall Charger
Connect
The following points must be observed when
installing on a wall:
– The basic construction of the wall must be such
that it can bear the weight of the fitted Wall
Charger Connect plus an additional 60 lbs
(27 kg).
– The following fastening points must be used
when installing on a wall:
– Solid wall: Use all four fastening points to
make the screw connection.
– Dividing wall/partition wall: Use the centre
fastening points at top and bottom to make
the screw connection.
– Use wall plugs to suit the wall.
– M8 flat screws are to be used for the screw
connection.
– To insert the screws, the bosses must be drilled
with an 8 mm drill bit.
– Only the screw bosses to be used may be drilled.
– To seal the screws, use the sealing washers
supplied.
– To mark the drill holes on the wall, use the drill
template supplied.
Connecting the cable
Electric shock, fire
DANGER
Incorrectly installed connections can cause electric
shock or fire when the high-voltage battery is
charged using the vehicle charge port.
e Switch off the supply voltage and make sure that
the voltage is off before installation works are
performed.
e Before the Wall Charger Connect is connected,
check which network configuration is available on
site. The Wall Charger Connect may only be used
with the network configurations listed here in the
corresponding arrangements. If you are unsure
about the network configuration, consult a
qualified electrician.
e Observe the locally applicable electrical
installation regulations, fire protection measures,
accident prevention regulations and escape
routes.