3) Unscrew the front panel (K) of the mounting bracket to access
the terminal block.
Attention
Never remove the cover located under the anemometer.
4) Unscrew the left-hand metal tab (L).
5) Drill a hole in the left-hand sealant pad (M).
Attention
• Never remove the sealant pad.
• The hole drilled in the pad must not exceed the diameter
of the cable in order to maintain tightness.
6) Feed the cable (B) through the sealant pad.
7) Connect the power supply cable (B) to the sensor using the
left-hand terminal block marked "230V" (N).
8) Screw in the metal tab (L): the cable must be fed under the
tab.
Attention
The cable sheath must exceed the tab by at least 2 mm.
͉
͉
To add the wiring for an Ondeis rain sensor, go to section 2.2.2.
9) Check the presence, good condition and the position of the
seal (V) before fitting the cover.
10) Screw the front panel (K) of the mounting bracket back on.
Attention
Tighten the screws completely to maintain the tightness of
the mounting bracket.
To complete the installation, go to section 2.3.
2.2.2. Connecting the Ondeis rain sensor to the Eolis io sensor
Attention
• In addition to the instructions provided in this manual, you must also comply with the
detailed instructions in the Ondeis rain sensor
• Perform disassembly and wiring operations away from any dust, moisture or foreign bodies
to maintain tightness.
͉
͉
To connect an Ondeis rain sensor after completing the procedure in section 2.2.1, go directly to step 4).