Determine Type of Solution Needed
,
Use only Manitowoc approved Ice Machine Cleaner
& Sanitizer. It is a violation of Federal law to use these
solutions in a manner inconsistent with their labeling.
Read and understand all labels on the bottles before use.
The iAuCS® accessory will dispense Cleaner OR Sanitizer. It
cannot dispense both at the same time.
MANITOWOC ICE MACHINE CLEANER
Part Number 9405463
Ice Machine Cleaner is used to control buildup and to remove
lime scale or other mineral deposits. It will not "sanitize" the
ice machine.
It is recommended for use in places that have lime scale or
other mineral deposits, but no problems with slime.
Model
22" or 30"
Ice Machine
48" Ice Machine
MANITOWOC ICE MACHINE SANITIZER
Part Number 9405653
Ice Machine Sanitizer is used for sanitizing and controlling
algae buildup (slime) and other bacterial growth. The ice
machine (and bin or dispenser) must be sanitized on a
regular schedule, following Manitowoc recommendations
and local regulations.
It is recommended for use in places such as pizzerias, bars,
bakeries, etc., that have airborne bacteria (yeast). Sanitizing
is also recommended in places that do not have lime scale
(or other mineral deposit problems).
Model
22" or 30"
Ice Machine
48" Ice Machine
Part Number 000009036 Rev03 9/18
Caution
Amount of Cleaner Dispensed
3 oz (88 ml)
6 oz (177 ml)
Amount of Sanitizer Dispensed
3 oz (88 ml)
6 oz (176 ml)
Section 3
Operation
Using the iAuCS® accessory is supplemental to regular
cleaning and sanitizing. The iAuCS® accessory will clean
surfaces that come in contact with the water distribution
system. Periodic maintenance must be performed every
six months that includes sanitizing the bin (or dispenser)
and adjacent surface areas, which cannot be contacted
by the water distribution system. Refer to the ice machine
installation operation and maintenance manual for
cleaning/sanitizing procedures.
Installing/Replacing Cleaner or Sanitizer Bottles
Do not mix Cleaner and Sanitizer solutions together. It
is a violation of Federal law to use these solutions in a
manner inconsistent with their labeling.
1. Remove left iAuCs®panel.
2. Unscrew nozzle/tubing from bottle, then remove bottle.
3. Remove bottle cap and foil seal from new bottle.
4. Install nozzle/tubing on new bottle.
5. Reinstall left panel.
Unscrew cap and remove bottle
Remove cap and foil seal from new
bottle and install
Important
Caution
,
15