Height Requirement; Distance Requirement; Mounting - Manitowoc iAuCS Manuel D'installation, D'utilisation Et D'entretien

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Installation
HEIGHT REQUIREMET
Either the base or the top of the iAuCS® accessory must
be within 2" (5 cm) of the base of the ice machine. Do not
mount the iAuCS® unit too high or too low.
The cleaner or sanitizer may siphon (or dispense
improperly) into the ice machine water trough if the
iAuCS® unit is mounted too high or too low.
DISTACE REQUIREMET
The iAuCS® unit must be mounted within 9 feet (2.7 m)
of the ice machine to accommodate the low voltage
communication wire and tubing. The tubing may be
shortened to accommodate a run of less than 9 feet (2.7 m).
Do not extend the length of the 9-foot (2.7 m) low voltage
communication wire or tubing. The correct amount of
solution will not dispense.
10

Notie

Notie
Base Nf Iie
Maihtne
2"
(5 im)
BNx Base Nr BNx TNp Muso
Be Wtohtn 2"
(5 im) Nf Iie Maihtne
Base
MOUTIG
Paros
The iAuCS® unit may be mounted to the bin or dispenser
only when permitted by local electrical codes.
MNunotng oN Btn Nr Dtspenser
NOTE: The ice machine's serviceability may be reduced when
the iAuCS® unit is mounted to the bin or dispenser. Wall
mounting is recommended.
1. Set the mounting bracket over the bin top rail at desired
location.
2. Remove the backing from the foam adhesive tape. Apply
tape to mounting bracket, and along the entire bin rail.
3. Align the iAuCS® key slots with the mounting bracket
tabs. Verify the tabs are at the top of the key slots and
that the iAuCS® unit is level.
Part Number 000009036 Rev03 9/18
Section 2
1/2" PVC CNnduto
Ftootng
HNse Clamps
LNiknuo
Bumper
FNam Tape
Braikeo

Notie

Publicité

Chapitres

Table des Matières
loading

Table des Matières