Indigo® Model Changing The Solution Type; Indigo® Model Manual Start Operation; Changing Switch Position During Operation - Manitowoc iAuCS Manuel D'installation, D'utilisation Et D'entretien

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Section 3
INDIGO® MODEL CHANGING THE SOLUTION TYPE
,
Wear rubber gloves and safety goggles (and/or face
shield) when handling Cleaner and Sanitizer.
,
Do not mix Cleaner and Sanitizer solutions together. It
is a violation of Federal law to use these solutions in a
manner inconsistent with their labeling.
Do not use 1 gallon bottles of Cleaner or Sanitizer on the
iAuCS® accessory.
Use the following procedure to flush the system prior to
changing from Cleaner to Sanitizer or from Sanitizer to
Cleaner.
1. Remove the bottle of Cleaner or Sanitizer from the
iAuCS®. Flush the bottle thoroughly then fill with water.
2. Repeat the following until the water bottle is empty
(approximately 8 times):
A. Press the CLEAN button.
B. The water pump and dump valve will turn on.
The dump valve will shut off after approximately
45 seconds.
C. The control waits until the water contacts the water
level probe then energizes the iAuCS® pump (22" or
30" ice machines - 30 seconds, 48" ice machines - 60
seconds).
D. Press the POWER button after step C is completed.
3. Install a new bottle of cleaner or sanitizer solution.
Part Number 000009036 Rev03 9/18
Caution
Caution

Notice
INDIGO® MODEL MANUAL START OPERATION
Step 1
Press the power button after ice falls from the
evaporator at the end of a Harvest cycle. Or, press the power
button and allow the ice to melt off the evaporator.
Never use anything to force ice from the evaporator.
Damage may result.
Step 2
To start the automatic cleaning system, press the
CLEAN button. The water will flow through the water dump
valve and down the drain. The clean light will turn on to
indicate the ice machine is in Clean Mode.
The iAuCS® pump energizes automatically to add cleaner or
sanitizer to the ice machine.
Step 3
The ice machine will automatically time out a wash
cycle, followed by rinse cycles, and stop. This entire cycle
lasts approximately 24 minutes for Indigo® Series.
Step 4
The ice machine will start and finish the clean
sequence, then automatically start ice making again.

CHANGING SWITCH POSITION DURING OPERATION

If a clean cycle is started and then stopped before the water
inlet valve energizes or the water pump starts (45 seconds
into the cycle), the clean cycle will be aborted.
If a clean cycle is started and then stopped after the water
inlet valve energizes (more than 45 seconds into the cycle)
and is then switched to:
ICE MAKING
The clean sequence resumes from the point of
interruption. After completion of the cleaning
sequence, the counter resets and the ice
machine starts making ice.
CLEAN
The clean sequence resumes from the point of
interruption.
After the clean cycle is complete, the ice
machine will stop and wait until either Ice
Making or Clean is manually selected.
After the iAuCs® pump energizes, the ice machine must
complete the wash and rinse cycles before ice making can
start.
Operation