General
These instructions are provided to assist the qualified
installer. Check your local Yellow Pages for the name of the
nearest distributor, or contact Manitowoc Ice for information
regarding start-up services.
Please contact you local Manitowoc Distributor or contact
Manitowoc Ice for assistance if you encounter a problem that
is not covered by this manual.
Failure to follow these installation guidelines may affect
warranty coverage. Improper installation will affect
dispensing rate. Install only within the parameters
outlined in this installation manual.
Eleiortial Servtie
GEERAL
n
A trained and qualified technician must install the iAuCS®.
VNloage Phase Cyile
115/1/60
208-230/1/60
Line voltage is obtained from the ice machine. Refer to the
Model/Serial plate on the ice machine and iAuCS® to verify
both voltages are the same.
Part Number 000009036 Rev03 9/18
Notie
Warntng
Amperage
0.3
0.1
SeiotNn 2
InsoallaotNn
tAuCS® InsoallaotNn
LOCATIO/MOUTIG
All wiring must conform to local, state and national codes.
The ice machine and iAuCS® must be grounded in
accordance with national and local electrical codes.
Observe correct polarity of incoming line voltage.
The location selected must meet the following criteria. If any
of these criteria are not met, select another location.
• The location must be free of airborne and other
contaminants.
• The air temperature must be at least 40°F (4°C), but must
not exceed 110°F (43°C).
• The location must not be near heat-generating
equipment or in direct sunlight.
The iAuCS® accessory must be protected if it will be
subjected to temperatures below 32°F (0°C). Failure
caused by exposure to freezing temperatures is not
covered by the warranty. See "Removal from Service/
Winterization" on page 20.
Warntng
n
Warntng
n
ImpNroano
Notie
9