Step 1
Ice must not be on the evaporator during the
clean/sanitize cycle. Follow one of the methods below:
• Press the power switch at the end of a harvest cycle after
ice falls from the evaporator(s).
• Press the power switch and allow the ice to melt.
• Use the touchscreen to initiate a manual harvest cycle
Menu/Service/Manual harvest/press to start harvest.
Step 2
Navigate to iAuCs® on the touchscreen:
Menu/Service/iAuCs®/Select On
A cleaning cycle will start by purging the water in the water
trough. When the water trough refills and water contacts
the water level probe, the iAuCs® pump will energize
(touchscreen displays step 4).
NOTE: After the iAuCs® pump dispenses, the washing, rinsing
and flushing cycles must complete before an ice making cycle
can start.
Step 3
The ice machine will turn off at the end of the
cycle. To automatically start ice making when the cycle
is complete, press the power button Off, then On during
the wash cycle (step 5 Washing is displayed). The clean
cycle will resume from the beginning of the washing cycle
and automatically start ice making when the clean cycle is
complete.

Important
Opening the curtain switch will interrupt the clean
sequence. The sequence will resume from the point of
interruption when the curtain re-closes.
Part Number 000009036 Rev03 9/18
INDIGO® NXT CHANGING THE SOLUTION TYPE
,
Wear rubber gloves and safety goggles (and/or face
shield) when handling Cleaner and Sanitizer.
,
Do not mix Cleaner and Sanitizer solutions together. It
is a violation of Federal law to use these solutions in a
manner inconsistent with their labeling.
Do not use 1 gallon bottles of Cleaner or Sanitizer on the
iAuCS® accessory.
Use the following procedure to flush the system prior to
changing from Cleaner to Sanitizer or from Sanitizer to
Cleaner.
1. Remove all ice from the evaporators before proceeding.
2. Remove the bottle of Cleaner or Sanitizer from the
iAuCS®. Flush the bottle thoroughly, then fill with water.
3. Repeat the following a minimum of two times:
A. Navigate to iAuCs® on the touchscreen and select :
Menu/Service/iAuCs®.
B. A cleaning cycle will start by purging the water in
the water trough. When the water trough refills and
water contacts the water level probe, the iAuCs®
pump will energize and prime the pump
4. Install a new bottle of cleaner or sanitizer solution.
Refer to "Installing/Replacing Cleaner or Sanitizer
Bottles" on page 15.