Installation Instructions
AuCS®-SO Installation
LOCATION / MOUNTING
!
All wiring must conform to local, state and national
codes.
!
The ice machine and AuCS®-SO must be grounded
in accordance with national and local electrical
codes.
Important
Observe correct polarity of incoming line voltage.
The location selected for the AuCS®-SO accessory
must meet the following criteria. If any of these criteria
are not met, select another location.
•
The location must be free of airborne and other
contaminants.
•
The air temperature must be at least 40°F (4°C), but
must not exceed 110°F (43°C).
•
The location must not be near heat-generating
equipment or in direct sunlight.
! Caution
The AuCS® accessory must be protected if it will be
subjected to temperatures below 32°F (0°C).
Failure
caused
by
temperatures is not covered by the warranty. See
"Removal from Service/Winterization".
6
Warning
Warning
exposure
to
freezing
HEIGHT REQUIREMENT
Either the base or the top of the AuCS®-SO accessory
must be within 2" (5 cm) of the base of the ice machine.
Do not mount the AuCS®-SO too high or too low.
! Caution
The cleaner or sanitizer may siphon (or dispense
improperly) into the ice machine water trough if the
AuCS®-SO is mounted too high or too low.
DISTANCE REQUIREMENT
The AuCS®-SO must be mounted within 9 feet (2.7 m)
of the ice machine to accommodate the low voltage
communication wire and tubing. The tubing may be
shortened to accommodate a run of less than 9 feet
(2.7 m).
! Caution
Do not extend the length of the 9-foot (2.7 m) low
voltage communication wire or tubing. The correct
amount of solution will not dispense.
Section 2
BASE OF ICE
MACHINE
2"
(5 cm)
BOX BASE OR BOX TOP
MUST BE WITHIN 2"
(5 cm) OF ICE MACHINE
BASE
Part Number 000007647 06/11