Pepperl+Fuchs KCT1-6SR-C Mode D'emploi page 25

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

<ESC>(A) CT Modifies the resolution at operating mode
TIMER and the position of the decimal
point
S = resolution seconds
M = resolution minutes
H = resolution hours
X = 0..3
W = resolution h:min:sec. No decimal point
=> X = 0
Value transmission in the following format:
<STX><S> or <M>
or <H> or
<W> X <CR><LF>
<ESC> (A) CU Reset mode for operating mode TIMER or
COUNT
0 = no reset
1 = electrical reset
2 = manual reset
3 = manual and electrical reset
Value transmission in the following format:
<STX> X <CR><LF>
<ESC> (A) D
Reading of the presets from the counter.
Preset 1 and preset 2 in the following for-
mat:
The device answers the query in the follo-
wing format:
<STX>
Type series KCT1-6SR-*:
<+/-> XXXXXX <CR><LF>
In addition, type series KCT1-6WR-*:
<+/-> XXXXXX <CR><LF>
<ESC> (A) E
Reading of the input filter setting
The device answers the query in the follo-
wing format:
ON = 30 Hz
OF = 20 kHz
<STX> <ON><CR><LF>
or
<STX> <OF><CR><LF>
<ESC> (A) G
Reading of the maximum dwell time at
operating mode TACHO
The device answers the query in the follo-
wing format:
<STX> XXX<CR><LF>
<ESC> (A) H
Transmits the counter identification and the
current software version.
The device answers the query in the follo-
wing format:
Y = software version
A = UART controller version
<STX> 71XVY.Y A<CR><LF>
Zumutbare Änderungen aufgrund technischer Verbesserungen vorbehalten.
Pepperl+Fuchs GmbH 68301 Mannheim Telefon (0621)776-11 11 Telefax (0621)776-27-11 11 Internet http://www.pepperl-fuchs.com
<ESC>(A) I
Operating mode COUNT: Reads the input
mode and the position of the decimal point.
X = 0: counting input and counting direction
input
X = 1: count input add + count input sub
X = 2: phase discriminator
X = 3: phase discriminator x 2
Y = 0..3
The device answers the query in the follo-
wing format:
<STX> XY <CR><LF>
<ESC>(A) J
Reads the sub operating mode at opera-
ting mode TIMER or COUNT.
The device answers the query in the follo-
wing format:
0 ≤ X ≤ 3 für "Add", "Sub", "AddAr", "SubAr"
<STX> X <CR><LF>
<ESC> (A) K0 Enables keyboard operation
<ESC> (A) K1 Disables keyboard operation
<ESC>(A) M
Reads the basic operating mode of the
counter
X = <F>: Frequency meter/Tachometer
X = <I>: Counter
X = <T>: Timer
The device answers the query in the follo-
wing format:
<STX> X <CR><LF>
<ESC>(A) P
Reads the input polarity
P = PNP
N = NPN
The device answers the query in the follo-
wing format:
<STX> <P><CR><LF>
or
<STX> <N><CR><LF>
<ESC>(A) R
Reads the display mode at operating mode
TACHO and the position of the decimal
point.
M = 1/min.
S = 1/sec.
X = 0..3
The device answers the query in the follo-
wing format:
<STX> <M> or <S> X <CR><LF>
<ESC> (A) S
Reads the start/stop mode at operatin
mode TIMER
0X = free run
1X = auto mode
2X = start inp B, stop inp B
3X = start inp A, stop inp B
X0 = gate low active
X1 = gate high active
The device answers the query in the follo-