5.3.2 Activation of the 30 Hz filter
max. counting frequency: 20 kHz
max. counting frequency: 30 Hz
5.3.3 Setting of the scale factor
Scale factor setting range from
00.0001 to 99.9999. Fixed decimal
point set to 4 decimal places.
A "0" setting is not accepted.
5.3.4 Decimal point setting
The decimal point determines the
number of decimal places dis-
played. It is only used for displaying
purposes and has no influence on
the counting.
0
0.0
0.00
0.000
5.3.5 Display mode
Conversion and display of the fre-
quency / speed in 1/sec.
Conversion and display of the fre-
quency / speed in 1/min.
5.3.6 Maximum pulse waiting time
This value indicates the time during which the device will
wait for a pulse before displaying a 0 speed.
Maximum delay 01.1 sec. (minimum
value)
Maximum delay 99.9 sec.
Values below 1.1 sec. are ignored and set automatically to
1.1 sec.
Zumutbare Änderungen aufgrund technischer Verbesserungen vorbehalten.
2
Pepperl+Fuchs GmbH 68301 Mannheim Telefon (0621)776-11 11 Telefax (0621)776-27-11 11 Internet http://www.pepperl-fuchs.com
no decimal place
one decimal place
two decimal places
three decimal places
5.3.7 Shape of output signal
Permanent signal. Is activated at
count value ≥ preset
Permanent signal. Will become
passive at count value ≥ preset
Timed signal. Will become passive
at count value ≥ preset
Timed signal. Is activated at count
value ≥ preset
5.3.8 Duration of the timed signal of the output
(only if a timed signal has been programmed in 5.3.7)
The duration can be set between
0.01 sec. and 99.99 sec.
A 0.00 setting is not accepted
5.3.12 End of programming
Programming is carried out once
more. The values input can be
checked and modified.
Programming is complete and the
values input are taken over as new
parameters.
Then the device is ready for opera-
tion.
6. Setting of the presets
If a push-button with an arrow or the "P" push-button is
pressed, the device jumps from the display of the counter to
the display of the preset. About 4 seconds after the last
operation of the button, the device jumps back to the dis-
play of the counter and takes over a new preset value.
Exception: in the time counter mode, the new value is
taken over immediately.
Once the preset is displayed, the " " push-button allows to
choose the decade to be modified. This decade then blinks
at a 1 Hz frequency. The "/" push-button allows you to raise
the value of the decade. On the most significant decade,
after the value "9", the sign "-" is displayed. The following
operation of the "/" push-button displays "-1" again. A new
operation of the "/" push-button lets the display of this de-
cade start again at "0".
Caution: in case of automatic repetition, the preset cannot
be given negative values.