5.1.7 Resetting mode
Manual (using the red push-button)
and electrical resetting
No resetting possible (red push-but-
ton and reset input idle)
Only electrical resetting
Only manual resetting
5.1.8 Shape of output signal
Permanent signal of the output,
activated at count value ≥ preset in
adding mode and at count value
in subtracting mode
Permanent signal of the output,
will become passive at count value
≥ preset in adding mode and at
count value
Timed signal of the output will be-
come passive at count value ≥ pre-
set in adding mode and at count
value
Timed signal of the output is acti-
vated at count value ≥ preset in
adding mode and at count value
in subtracting mode
5.1.9 Duration of the timed signal
(only if a timed signal has been programmed in 5.1.8)
The duration can be set between
0.01 sec. and 99.99 sec.
A 0.00 setting is not accepted
5.1.10 End of programming
Programming is carried out once
more. The values input can be
checked and modified.
Programming is complete and the
values input are taken over as new
parameters.
Then the device is ready for opera-
tion.
Zumutbare Änderungen aufgrund technischer Verbesserungen vorbehalten.
18
Pepperl+Fuchs GmbH 68301 Mannheim Telefon (0621)776-11 11 Telefax (0621)776-27-11 11 Internet http://www.pepperl-fuchs.com
0 in subtracting mode
0 in subtracting mode
5.2 Time meter mode setting
5.2.1 Sub operating mode
0
5.2.2 Polarity of the inputs
5.2.4 Start and stop of time counting
0
Copyright Pepperl+Fuchs, Printed in Germany
Adding
Outputs active at count value ≥
preset
Resetting to zero
Subtracting
Output active at count value
Resetting to preset
Adding
Output active at count value =
preset
Automatic reset to zero
Resetting to zero
Subtracting
Output active at count value = 0
Automatic positioning to preset
Resetting to preset
npn: switching to 0 V
pnp: switching to +24 V
A pulse on INP B starts the count-
ing, the following pulse on INP B
stops it (raising pulse edge for pnp,
descending pulse edge for npn).
A pulse on INP A starts the count-
ing, a pulse on INP B stops it (rais-
ing pulse edge for pnp, descending
pulse edge for npn).
The counting can only be controlled
by means of the GATE input. INP A
and INP B have no function.
The counter is reset by a reset sig-
nal (manual or electrical) (to 0 when
adding, to preset when subtracting),
then counting starts. Counting is
stopped when the adding counting
reaches preset or when the sub-
tracting counting reaches 0. A reset
signal during counting also stops
the counting. INP A and INP B have
no function.
0