Output :
Outputs response time:
Data storage:
Sensor supply voltage:
EMC:
Noise emission:
Noise immunity:
Device safety
Design to:
Protection Class:
Application area:
Operating temperature: -10°C.. +50°C
Storage temperature:
Altitude:
Weight:
Protection:
Housing colour:
Cleaning:
9. Delivery specification
• Counter KCT1-6SR-*
• Screw terminal (7 poles) pitch 5,08 mm.
• Screw terminal (7 poles) pitch 3,81 mm.
• Frame for screw mounting, opening 50 x 50 mm
• Frame for clamp mounting, opening 50 x 50 mm
• Clamp
• With the serial interface option: screw terminal (5 poles)
Pitch 3,81 mm.
Zumutbare Änderungen aufgrund technischer Verbesserungen vorbehalten.
22
Pepperl+Fuchs GmbH 68301 Mannheim Telefon (0621)776-11 11 Telefax (0621)776-27-11 11 Internet http://www.pepperl-fuchs.com
Relay with potential-free
change-over contact, programma-
ble as opening or closing contact.
Switching voltage
max. 250VAC/300 VDC.
Switching current max. 3A
Switching current min. 30 mADC
Switching power 50 W / 2000 VA
or npn optocoupler with open
collector and emitter
Switching power: 30 VDC /15mA
U
for lC = 15 mA:
CESAT
max. 2.0 VDC
U
for lC = 5 mA:
CESAT
max. 0.4 VDC
U
= voltage drop on
CESAT
optocoupler at current l
C
Relay: approx. 7 ms
Optocoupler: approx. 2 ms
at least 10 years or 106
recording cycles (switching on
and off the device)
+24 VDC ± 15 % / 100 mA
with AC power supply
EN 55 011 Class B
EN 61 000-6-2
EN 61010 Part 1
Class 2
Soiling Level 2
-25°C..+70°C
to 2000 m
approx. 200 g (AC version with
relay)
IP 65 (front side)
dark grey
The front side of the device
must be cleaned only with a
damp soft cloth.
10. Order code
KCT1-6SR-C
KCT1-6SR-V
11. Dimensions
Copyright Pepperl+Fuchs, Printed in Germany