14
It is easiest to prepare for installation with the heater lying down.
To install the heater:
2.
Remove the cover to the water reservoir and lay the heater
down with the front facing upwards. Install the
knob (see Figure 9).
3.
Undo the screws and open the cover (see Figure 9).
Figure 9: Opening/closing the cover
WARNING! Always check that the heater is con-
nected to the correct main/phase voltage!
Connect the heater using standard wiring (Fk or EKK) approved
for fi xed installation.
Any single wires (Fk) must be protected in electrical conduits (VP)
to the heater.
4.
Connect the electrical cable (see Figure 10) according to the
wiring diagram (see Figure 17).
6
11
5
7
Figure 10: Circuit board
1.
Electrical cable
2.
Terminal for connection of
electrical cable
3.
Cable grommet (x5)
4.
Control panel cable
5.
Modular contacts for connec-
tion of control panel, sensor
etc.
4
9
3
1
8
2
6.
Sensor cable
7.
Light cable (if relevant)
8.
Terminal for connection of light
(if relevant)
9.
Strain relief connector for ca-
bles to modular contacts (x2)
10. Strain relief connector for
electrical cable
11. Protection hose for RJ10
cables
5.
Run the cables for the control panel and the temperature
sensor through the cable grommets (see Figure 10). Connect
the control panel cable to one of the four RS485 contacts
(positions 6-9) (see Figure 19, 20).
6.
Combi Pure: Connect the sensor cable to the NTC
contact on the circuit board (position 1) (see Figure 20).
Combi Elite: Connect the humidity- and temperature sensors
cable to one of the four RS485 contacts (positions 6-9)
(see Figure 19).
7.
Connect the light cable (if relevant) (7), see Figure 10, accor-
ding to the wiring diagram Figure 17.
8.
Close the cover and tighten the screws (see Figure 9).
9.
Hang the heater on the bracket (see Figure 11).
Figure 11: Hang the heater up.
10. Fit the spacers between heater and wall (to prevent the hea-
ter from being lifted off ) (see Figure 12).
10
Fig 12: Fit spacers