Accessories Supplied Separately - RHOSS WinPACK HE-A SE TCAEY B-S 2110 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

RS
DS
Desuperheater. Also active during winter operation (THAEY)
RC100
Heat recovery unit with 100% recovery
FI10
Modulating condensation control for continuous operation
as chiller up to -10°C of outdoor air temperature
(standard versions S)
FI15
Modulating condensation control with fans with EC motor
(Brushless) for continuous operation as a chiller up to
-15°C outdoor air temperature (standard Q versions)
FIAP
Condensation control with over-pressured fans with EC
motor (Brushless) and available static head up to 150 Pa
(for for B-T versions)
SFS
Soft Starter compressors
CR
EEV
Electronic thermostatic valve
(standard supplied in versions T-Q)
FDL
Forced Download Compressors. Compressor switch-off to
limit the absorbed current and power (digital input)
FNR
Forced Noise Reduction. Forced reduction of noise (digital
more information)
GM
Refrigerant circuit high and low pressure gauges.
RQE
Electrical panel resistance
(recommended for low outdoor air temperatures)
RA
Evaporator antifreeze resistor to prevent the risk of ice formation
inside the exchanger when the machine is switched off (as long
as the unit is not disconnected from the power supply)
RDR
Antifreeze electric heater for desuperheater / heat re-
covery (DS or RC100), to prevent the risk of ice forma-
tion inside the recovery exchanger when the machine is
switched off (as long is the unit is not disconnected from
the power supply)
RAE1-
27W antifreeze electric heater for motor-driven pump
RAR1
(available for P1-DP1-ASP1-ASDP1 installations); to
prevent the water contained in the pump from freezing
when the machine is switched off (as long as the unit is
not disconnected from the power supply)
RAE2-
27W antifreeze electric heater for double motor-driven
RAR2
pumps (available for DP1-DP2-DPR1-DPR2-ASDP1-
ASDP2 installations); to prevent the water contained in the
pump from freezing when the machine is switched off (as
long as the unit is not disconnected from the power supply)
RAS
300W antifreeze electric heater for water buffer tank
(available for ASP1-ASDP1- ASP2-ASDP2 installations);
to prevent the risk of ice formation in the water buffer tank
when the machine is switched off (as long as the unit is
not disconnected from the power supply)
RIS
Integrative electrical resistances and the Antifreeze stor-
age tank (only with Tank&Pump - incompatible with RAS)
LDK
Refrigerant leak detector
DSP
Double set-point via digital consensus
(incompatible with the CS accessory)
CS
Scrolling set point via analogue signal 4-20 mA (incompat-
ible with the DSP accessory). The EEV accessory may
have to be also installed, depending on the required values
CMT
Control of minimum and maximum values of power voltage
BT
Low temperature of water produced
SS
RS485 interface for serial communication with other de-
vices (proprietary protocol; Modbus RTU protocol).
EEM
Energy Meter. Measure and display values of the electri-
Section II :: Installation and maintenance
67
EEO
FTT10
LON interface for serial communication with other devices
(LON protocol).
RPB
Protection coil grilles with accident-prevention function (to
use as an alternative to the FMB accessory)
(not available with V-coiled models)
FMB
function (to use as an alternative to the RPB accessory)
(not available with V-coiled models)
RAP
Unit with copper/copper condensation coils (available as
an alternative in chillers with traditional Cu-AL coils and
heat pumps - refer to the table in "General features")
BRR
Unit with copper/copper condensation coils (available as
an alternative in chillers with traditional Cu-AL coils and
heat pumps - refer to the table in "General features")
DVS
Double high pressure safety valve with an exchanger
valve (the valve is only on the outlet branch. In the case
of options, such as DS/RC100 recovery units or tube
and shell heat exchangers, please contact the Pre-Sales
department for a quotation and feasibility of the additional
double valves)
IMB
Protective packaging
SAG
Rubber anti-vibration mountings (supplied not installed)
SAM
Spring anti-vibration mountings (supplied not installed)
TQE
Electrical panel roof
MCHXE
AL/AL micro-channel coil with E-coating treatment
(available in chillers with micro-channel coils)

Accessories supplied separately

KTRD
Thermostat with display
KTR
Remote keypad for control at a distance with LCD
display and same functions as the machine connection
must be made with a 6-wire telephone cable (maximum
distance 50 m) or with KRJ1220/KRJ1230 accessories.
For greater distances up to 200 m, use an AWG 20/22
KR200 accessory.
KRJ1220 Connection cables for KTR (20 m length)
KRJ1230 Connection cables for KTR (30 m length)
KR200
KTR remote control Kit (distance between 50 and 200m)
KBE
Ethernet interface for serial communication with other
devices (BACnet IP protocol)
KBM
RS485 interface for serial communication with other
devices (BACnet MS/TP protocol)
KUSB
RS485/USB serial converter (USB cable supplied)
sory.