EN
TCAESY SE Model (double circuit)
Nominal cooling capacity (*)
EER
Nominal cooling capacity (*) (°) EN 14511:2013
EER (*) (°) EN 14511:2013
ESEER EN 14511:2013
Sound pressure (***) (*)
Sound power (****) (*)
Scroll/step compressor
Circuits
Fans
Heat exchanger
Water side heat exchanger nominal pressure drops (*)
Residual head P1 (*)
Residual head P2 (*)
Residual head ASP1 (*)
Residual head ASP2 (*)
Tank water content (ASP1/ASP2)
Nominal heating capacity RC100 (±)
Nominal heating capacity DS (±)
Amount of R410A refrigerant
Polyester oil charge
Electrical data
Pump absorbed power (P1/ASP1) / (P2/ASP2)
Electrical power supply
Auxiliary electrical
Pump absorbed current (P1/ASP1) / (P2/ASP2)
Dimensions
Height (a)
Width (b)
Length (c)
Heat exchanger inlet/outlet connections and RC100
DS inlet/outlet connections
Weight
(*) Under the following conditions: condenser inlet air temperature
35°C; chilled water temperature 7°C; temperature differential at
evaporator 5 K; fouling factor equal to 0.35x10-4 m2 K/W.
(***) Sound pressure level in dB(A) referring to a 10 m distance from
data refers to the units without the electric pump
(****) Sound power level in dB(A) on the basis of measurements taken
in accordance with UNI EN-ISO 9614 and Eurovent 8/1 Standards
The noise data refers to the units without the electric pump
Enclosed documents
4150
4170
4200
kW
143
162
2,98
2,86
2,71
4,98
4,97
4,85
kW
142,3
161,4
182,3
2,93
2,82
2,67
4,25
4,23
4,10
dB(A)
51
51
dB(A)
83
83
n°
4/4
4/4
n°
2
2
n° x kW
3x1,2
3x1,2
3x1,2
m³/h
46000
46000
46000
Type
Plates/Shell and tube (STE accessory)
m³/h
24,6
27,9
31,5
kPa
42
29
kPa
120
121
kPa
160
164
kPa
114
114
kPa
155
157
l
300
300
kW
189
217
m³/h/kPa
32,5/73
37,3/51
42,8/67
kW
36
41
m³/h/kPa
3,1/13
3,5/11
4/12
Kg
16
18
Kg
10,6
10,6
10,6
4150
4170
4200
kW
48,0
56,6
67,5
kW
2,2/3,0
2,2/3,0
2,2/3,0
V-ph-Hz
V-ph-Hz
A
80
94
A
104
120
A
226
269
A
168
199
A
4,5/6,0
4,5/6,0
4,5/6,0
4150
4170
4200
mm
2440
2440
2440
mm
1350
1350
1350
mm
3600
3600
3600
Ø
2"½ vic
2"½ vic
2"½ vic
Ø
1"¼ vic
1"¼ vic
1"¼ vic
Kg
1300
1320
1325
(±) Recovery unit heating capacity Conditions referring to the unit
operating with chilled water temperature 7°C, differential temperature
due to evaporation of 5 K, hot water temperature produced equivalent
to 40/45°C (RC100) 50/60°C (DS). NB. With heat pumps operat-
ing in winter mode with DC active, the heating capacity available is
decreased from the portion supplied to the desuperheater.
( ) Absorbed current/absorbed power value without electric pump.
The starting current refers to the worst conditions of the unit.
(°) Data calculated in accordance with EN 14511:2011 under nominal
conditions.
The refrigerant charge values are indicative. Refer to the
serial number plate.
288
4220
4240
4270
183
208
225
251
2,86
2,71
2,7
4,95
4,83
4,83
207,2
224,2
250,1
2,82
2,68
2,66
4,19
4,11
4,11
51
52
54
54
83
84
86
86
4/4
4/4
4/4
4/4
2
2
2
2
4x1,2
4x1,2
4x1,2
61500
62000
62000
35,8
38,7
43,2
36
37
35
42
104
83
105
92
148
127
146
133
96
72
98
84
140
116
139
126
300
550
550
550
249
277
302
338
47,6/68
51,9/63
58,1/75
47
53
59
65
4,6/11
5,1/13
5,6/11
18
22
26
26
10,6
20,8
20,8
4220
4240
4270
72,7
83
93
2,2/3,0
3,0/4,0
3,0/4,0
400 – 3 – 50
230 – 1 – 50
112
121
138
154
136
156
192
208
313
333
362
370
228
248
278
286
4,5/6,0
6,0/8,0
6,0/8,0
4220
4240
4270
2440
2440
2440
1350
1350
1350
3600
4550
4550
2"½ vic
3" vic
3" vic
1"¼ vic
1"¼ vic
1"¼ vic
1470
1830
1850
4310
4340
292
321
2,71
2,65
4,81
4,75
291
319,7
2,68
2,61
4,06
4,02
56
57
88
89
4/4
4/4
2
2
6x1,2
6x1,2
81600
81600
50,2
55,2
40
46
106
88
163
145
100
82
157
138
700
700
393
434
67,6/72
74,6/85
76
84
6,5/12
7,2/11
50
50
20,8
20,8
4310
4340
107,7
121,1
4,0/5,5
4,0/5,5
179
201
242
268
468
494
366
379
8,0/10,5
8,0/10,5
4310
4340
2030
2030
2090
2090
4800
4800
3" vic
3" vic
2" vic
2" vic
2440
2450