RHOSS WinPACK HE-A SE TCAEY B-S 2110 Mode D'emploi page 295

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Model THAETY HE-A
Nominal cooling capacity (*)
EER
Nominal cooling capacity (*) (°) EN 14511:2013
EER (*) (°) EN 14511:2013
ESEER EN 14511:2013
Nominal heating capacity (**)
COP
Nominal heating capacity (**) (°) EN 14511:2013
COP (*) (°) EN 14511:2013
Sound pressure (***) (*)
Sound power (****) (*)
Sound power with FNR accessory (****)(*)
Scroll/step compressor
Circuits
Fans
Heat exchanger
Water side heat exchanger nominal pressure drops (*)
Residual head P1 (*)
Residual head P2 (*)
Residual head ASP1 (*)
Residual head ASP2 (*)
Tank water content (ASP1/ASP2)
Nominal heating capacity RC100 (±)
Nominal heating capacity DS (±)
Amount of R410A refrigerant
Polyester oil charge
Electrical data
Pump absorbed power (P1/ASP1) / (P2/ASP2)
Electrical power supply
Auxiliary electrical
Pump absorbed current (P1/ASP1) / (P2/ASP2)
Dimensions
Height (a)
Width (b)
Length (c)
Heat exchanger inlet/outlet connections and RC100
DS inlet/outlet connections
Weight
(*) Under the following conditions: condenser
inlet air temperature 35°C; chilled water
temperature 7°C; temperature differential
at evaporator 5 K; fouling factor equal to
0.35x10-4 m2 K/W.
(**) Under the following conditions: evaporator
inlet air temperature 7°C B.S., 6°C B.U.; hot
water temperature 45°C; temperature differ-
ential at condenser 5 K; fouling factor equal to
0.35x10-4 m2 K/W.
(***) Sound pressure level in dB(A) referring to
directionality factor equal to Q=2. The noise
Enclosed documents
2110
2120
kW
102
113
2,88
2,86
4,69
4,73
kW
101,6 112,6 126,5 145,4 161,4 186,3 209,3 231,3 263,3 301,1 334,1
2,83
2,82
4,00
4,01
kW
114
124
3,25
3,25
kW
114,5 124,5 141,6 161,6 181,7 204,8 233,9 249,8 282,8
3,22
3,22
dB(A)
53
54
dB(A)
85
86
dB(A)
79
79
2/3
2/3
1
1
n° x kW
2x1,8 2x1,8 3x1,8 3x1,8 3x1,8 4x1,8 4x1,8 4x1,8 6x1,8 6x1,8 8x1,8
m³/h
41200 41200 59400 58200 62000 79200 77600 78800 106200 111000 134200
Type
m³/h
17,5
19,4
kPa
32
29
kPa
100
100
kPa
144
143
kPa
97
96
kPa
141
140
l
300
300
kW
133
148
m³/h/kPa
22,9/55 25,5/50 28,4/55 32,7/55 36,5/52 42/57 47,3/57 52,4/45 59/43 67,8/53 75/50
kW
26
29
m³/h/kPa
2,2/5
2,5/6
Kg
38
39
Kg
10,4
10,4
2110
2120
kW
35,4
39,5
kW
35,1
38,2
kW
1,5/2,2 1,5/2,2 1,5/2,2 2,2/3,0 2,2/3,0 2,2/3,0 2,2/3,0 3,0/4,0 3,0/4,0 4,0/5,5 4,0/5,5
V-ph-Hz
V-ph-Hz
A
59
66
A
86
96
A
248
266
A
164
182
A
3,0/4,5 3,0/4,5 3,0/4,5 4,5/6,0 4,5/6,0 4,5/6,0 4,5/6,0 6,0/8,0 6,0/8,0 8,0/10,5 8,0/10,5
2110
2120
mm
2440
2440
mm
1350
1350
mm
3600
3600
Ø
2"½ vic 2"½ vic 2"½ vic 2"½ vic 2"½ vic 2"½ vic 2"½ vic 3" vic 3" vic 3" vic 3" vic
Ø
1" GM 1" GM 1" GM 1" GM 1" GM 1" GM 1" GM 2" vic 2" vic 2" vic 2" vic
Kg
1380
1410
data refers to the units without the electric
pump
(****) Sound power level in dB(A) on the basis of
measurements taken in accordance with UNI EN-
ISO 9614 and Eurovent 8/1 Standards The noise
data refers to the units without the electric pump
(±) Recovery unit heating capacity Conditions
referring to the unit operating with chilled water
temperature 7°C, differential temperature due
to evaporation of 5 K, hot water temperature
produced equivalent to 40/45°C (RC100) 50/60°C
(DS). NB. With heat pumps operating in winter
295
2140
2150
2170
2200
2220
127
146
162
187
210
2,86
2,87
2,84
2,83
2,83
4,66
4,67
4,69
4,53
4,60
2,82
2,83
2,8
2,79
2,79
3,89
3,96
3,99
3,87
3,91
141
161
181
204
233
3,24
3,25
3,26
3,25
3,24
3,21
3,22
3,23
3,22
3,21
55
55
56
57
87
87
88
89
80
80
81
82
2/2
2/3
2/2
2/3
1
1
1
1
Plates/Shell and tube (STE accessory)
21,8
25,1
27,9
32,2
36,1
32
32
30
33
90
124
117
99
133
166
160
143
126
86
118
110
90
129
160
153
133
114
300
300
550
550
550
165
190
212
244
275
33
38
41
47
2,8/7
3,3/6
3,5/6
4/8
4,6/7 5,2/14 5,7/11 6,5/12 7,3/12
40
51
64
65
10,4
10,4
10,4
10,4
10,4
2140
2150
2170
2200
2220
44,4
50,9
57
66,1
74,2
43,5
49,5
55,5
62,8
71,9
400 – 3 – 50
230 – 1 – 50
74
84
95
110
123
108
121
134
153
168
270
347
360
379
390
186
232
245
256
270
2140
2150
2170
2200
2220
2440
2440
2440
2440
2440
1350
1350
1350
1350
1350
3600
3600
4450
4450
4550
1420
1500
1670
1690
1780
mode with DC active, the heating capacity avail-
able is decreased from the portion supplied to the
desuperheater.
( ) Absorbed current/absorbed power value without
electric pump.
The starting current refers to the worst conditions of
the unit.
(°) Data calculated in accordance with EN
14511:2011 under nominal conditions.
The refrigerant charge values are indicative. Refer
to the serial number plate.
4240
4270
4310
4340
232
264
302
335
2,82
2,86
2,85
2,83
4,85
4,79
4,75
4,74
2,79
2,83
2,82
2,8
4,10
4,04
4,04
3,99
249
282
320
356
3,22
3,22
3,22
3,22
321
357
3,2
3,2
3,2
3,2
57
58
60
60
62
89
90
92
92
94
82
83
85
85
86
2/2
4/4
4/4
4/4
4/4
1
2
2
2
2
39,9
45,4
51,9
57,6
33
26
25
31
29
83
101
90
110
91
142
132
166
146
71
98
85
104
83
139
127
160
138
700
700
700
700
305
343
394
436
54
60
66
76
85
79
79
82
91
95
20,8
20,8
20,8
20,8
4240
4270
4310
4340
82,3
92,3
106
118,4
77,3
87,6
99,4
110,6
137
153
176
197
192
208
242
268
362
378
468
502
278
294
366
387
4240
4270
4310
4340
2030
2030
2030
2030
2090
2090
2090
2090
4800
4800
5300
5300
2470
2570
2720
2840
EN

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Winpack he-a se tcaey b-s 2120Winpack he-a se tcaey b-s 2140Winpack he-a se tcaey b-s 2150Winpack he-a se tcaey b-s 2170Winpack he-a se tcaey b-s 2200Winpack he-a se tcaey b-s 2220 ... Afficher tout

Table des Matières