TECHNICAL DATA
TCAEBY SE Model (single circuit)
Nominal cooling capacity (*)
EER
Nominal cooling capacity (*) (°) EN 14511:2013
EER (*) (°) EN 14511:2013
ESEER EN 14511:2013
Sound pressure (***) (*)
Sound power (****) (*)
Sound power with FNR accessory (****)(*)
Scroll/step compressor
Circuits
Fans
Heat exchanger
Water side heat exchanger nominal pressure drops (*)
Residual head P1 (*)
Residual head P2 (*)
Residual head ASP1 (*)
Residual head ASP2 (*)
Tank water content (ASP1/ASP2)
Nominal heating capacity RC100 (±)
Nominal heating capacity DS (±)
Amount of R410A refrigerant
Polyester oil charge
Electrical data
Pump absorbed power (P1/ASP1) / (P2/ASP2)
Electrical power supply
Auxiliary electrical
Pump absorbed current (P1/ASP1) / (P2/ASP2)
Dimensions
Height (a)
Width (b)
Length (c)
Heat exchanger inlet/outlet connections and RC100
DS inlet/outlet connections
Weight
(*) Under the following conditions: condenser inlet air temperature
35°C; chilled water temperature 7°C; temperature differential at
evaporator 5 K; fouling factor equal to 0.35x10-4 m2 K/W.
(***) Sound pressure level in dB(A) referring to a 10 m distance from
data refers to the units without the electric pump
(****) Sound power level in dB(A) on the basis of measurements taken
in accordance with UNI EN-ISO 9614 and Eurovent 8/1 Standards
The noise data refers to the units without the electric pump
Enclosed documents
2110
2120
kW
107
115
2,86
2,85
4,62
4,63
kW
106,5
114,4
2,81
2,79
3,91
3,94
dB(A)
55
56
dB(A)
87
88
dB(A)
81
82
n°
2/3
2/3
n°
1
1
n° x kW
2 x1,8
2 x1,8
m³/h
39600
39600
Type
Plates/Shell and tube (STE accessory)
m³/h
18,4
19,8
kPa
39
44
kPa
93
85
kPa
137
128
kPa
90
82
kPa
134
125
l
300
300
kW
140
151
m³/h/kPa
24,1/67
26/76
kW
28
29
m³/h/kPa
2,4/7
2,5/8
Kg
13
13
Kg
10,4
10,4
2110
2120
kW
37,4
40,4
kW
1,5/2,2
1,5/2,2
V-ph-Hz
V-ph-Hz
A
62
67
A
86
96
A
248
266
A
164
182
A
3,0/4,5
3,0/4,5
2110
2120
mm
2440
2440
mm
1350
1350
mm
2650
2650
Ø
2"½ vic
2"½ vic
Ø
1" GM
1" GM
Kg
990
1000
(±) Recovery unit heating capacity Conditions referring to the unit
operating with chilled water temperature 7°C, differential temperature
due to evaporation of 5 K, hot water temperature produced equivalent
to 40/45°C (RC100) 50/60°C (DS). NB. With heat pumps operat-
ing in winter mode with DC active, the heating capacity available is
decreased from the portion supplied to the desuperheater.
( ) Absorbed current/absorbed power value without electric
pump.
The starting current refers to the worst conditions of the unit.
(°) Data calculated in accordance with EN 14511:2013 under
nominal conditions.
The refrigerant charge values are indicative. Refer to the
serial number plate.
285
2140
2150
2170
128
148
166
2,85
2,86
2,86
4,66
4,52
4,61
127,4
147,3
165,2
2,8
2,81
2,81
3,96
3,85
3,93
56
57
58
88
89
90
82
83
84
2/2
2/3
2/2
1
1
1
2 x1,8
3 x1,8
3 x1,8
39600
59600
59600
22
25,4
28,5
44
48
48
80
108
99
123
149
142
76
102
92
119
144
135
300
300
300
168
193
217
28,9/76
33,2/82
37,3/83
33
38
43
2,8/7
3,3/8
3,7/7
14
17
18
10,4
10,4
10,4
2140
2150
2170
44,9
51,7
58
1,5/2,2
2,2/3,0
2,2/3,0
400 – 3 – 50
230 – 1 – 50
75
86
96
104
121
134
266
347
360
182
232
245
3,0/4,5
4,5/6,0
4,5/6,0
2140
2150
2170
2440
2440
2440
1350
1350
1350
2650
3600
3600
2"½ vic
2"½ vic
2"½ vic
1" GM
1" GM
1" GM
1010
1160
1180
EN
2200
2220
189
213
2,85
2,85
4,75
4,57
188,1
212,1
2,8
2,8
4,00
3,87
58
59
90
91
84
85
2/3
2/2
1
1
3 x1,8
4 x1,8
59600
79200
32,5
36,6
47
47
87
68
130
111
77
56
121
100
300
550
248
279
42,6/82
48/81
49
55
4,2/9
4,7/8
19
23
10,4
10,4
2200
2220
66,3
74,7
2,2/3,0
2,2/3,0
110
124
149
168
375
390
252
270
4,5/6,0
4,5/6,0
2200
2220
2440
2440
1350
1350
3600
4550
2"½ vic
2"½ vic
1" GM
1" GM
1180
1340