OMNIA HL - HL M FANCOIL
The OMNIA HL (High Line) fancoil, with its characteristic
design by Studio Giugiaro, offers an array of technical featu-
res that make it the ideal climate-control unit for all types of
applications.
Treated air is immediately delivered to the entire room;
the OMNIA HL produces warm air when fitted to a heating
system with boiler or heat pump, but can also be used
during the summer season as an air-conditioning unit (if the
main system is also equipped with a water chiller).
The quality of processed air is guaranteed by a special
electrostatically pre-charged filter that absorbs and traps
suspended dust particles (when the unit is off, a closed lou-
ver prevents dust and other foreign particles from entering
the unit interior). The removable drip tray and fan volute
ensure thorough cleaning of the unit (should be performed
by a technician who has the necessary technical and profes-
sional expertise to install, modify, extend and maintain
VERSIONS:
HL
RAL9002 white body with switch. The air distribution head and the skirts are in RAL7044.
HL M
FIAT656 metallic grey body with switch. The air distribution head and the skirts are in RAL7031 grey.
SELECTOR (A)
- On/Off
- Manual speed selection
V1 =Minimun fan speed
V2 =Mediun fan speed
V3 =Maximun fan speed
USE (OMNIA HL - HL M)
CONTROLS:
Ventilation is only permitted when the louver is manually
opened. When the louvers are closed, ventilation is shut
down.
On / Off
OFF
The fancoil is off.
To restart the fancoil, rotate the knob to the ope-
ration mode required in one of the three fan
speeds.
8
plants and who is able to check the plants for the purposes
of safety and correct operation), essential for installations in
venues subject to crowding or in those with special hygiene
requirements.
The new centrifugal fan assembly is so quiet that during
standard operation it's virtually impossible to hear when the
OMNIA HL starts up.
The control panel with switch is protected by a panel on
the unit head.
With its large range of accessories, the OMNIA HL fancoil
is designed to satisfy all installation types.
The unit can be easily installed either vertically or hori-
zontally (water connections can be reversed as required
during installation).
Full compliance with safety regulations.
Routine maintenance is limited to periodic cleaning of the
air filter in water.