Connection Of As Interface - Lenze starttec type1 Instructions De Montage

Démarreur moteur
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

)
Note!
The AS interface is only active with starttec type
)
Note!
If the mains voltage is switched on and no supply voltage DC 24 V is
applied, the AS−i status bits have the value TRUE. This may cause the status
messages to be misanalysed (e. g. "ready for operation").
Remedy:
Monitor the incoming cable of the supply voltage DC 24 V for wire
l
breakage. The wire breakage monitoring must be integrated into the
safety chain of the machine/system.
or
Assign an AS−i status bit with the signal "TRIP":
l
C0415/5 = 25 or C0415/6 = 25
Then, "TRIP" is also signalling, when the supply voltage DC 24 V is not
applied anymore.
Communications data
Protocol / communication medium
Network topology
Node
Slave profile
Operating parameters
Data structure
Max. number of nodes
Transfer rate [kbit/s]
Cycle time [ms]
Max. bus length [m]
L
Electrical installation

Connection of AS interface

AS−I
Tree
Slave
S−7.F (IO code: 7
, ID code: F
hex
F
hex
3 AS−I data bits (D0, D1, D2) to starttec
2 AS−I data bits (D0, D1) from starttec
31
167
5 ms (with 31 nodes)
100
EDK71MMXXX−010 DE/EN/FR 5.0
E71MM402FxAxxx!−23−
)
hex
5
91

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

E71mm402 x a 2a 22 série

Table des Matières