WARNING
!
•
Risk of fi re! Maintain specifi ed air space clearances to vent pipe and appliance.
Clean out ashes from the inside of the wood-burning appliance. Make sure that the chimney and wood-burning
appliance are in a clean and sound condition and constructed of non-combustible materials. If necessary have any
repair work done by a qualifi ed person before installing the insert. Remove the existing appliance damper or lock
into an open position.
Using screws, attach the appliance warning tag to the inside
of the fi rebox of the appliance into which the insert is being
installed.
The sheet-metal parts of the appliance, in which the gas
appliance insert is to be installed, must not be cut.
If the wood-burning factory-built appliance has no gas access
hole(s) provided, an access hole of 1½ inch (38.1mm) or less
may be drilled through the lower sides or bottom of the appliance in a proper workman like manner. This access
hole must be plugged with non-combustible insulation after the gas supply line has been installed.
Ensure that existing chimney cleanouts fi t properly.
The refractory, glass doors, screen rails, screen mesh and log grates may be removed from the existing appliance
before installing the gas appliance insert.
Smoke shelves, shields and baffl es may be removed if attached by mechanical fasteners.
The ventilation openings in the existing appliance may be obstructed by the backer plates, aluminium trim etc. but
these parts are not to be applied so as to have an airtight seal.
f i r e - p a r t s . c o m
2.1
levelling the appliance
Have an authorized dealer install the appliance. If you install the appliance yourself, have your dealer review your
installation plans and/or installation. Draw out a detailed plan of the installation including dimensions and verify the
dimensions with the requirements listed in this manual.
You may wish to adjust the appliance position slightly to ensure the vent does not intersect with a framing
member. Appliance must be positioned so that no combustibles are within, or can swing within (e.g. drapes,
doors), 48" (121.9cm) of the front of the appliance.
Inserts only: This appliance is equipped with levelling screws, level the appliance before installing into the fi nal
Inserts only: This appliance is equipped with 4 levelling legs. Level the appliance before installing into the final po-
position. Levelling the appliance will eliminate rocking or excessive noise when the fan is in operation. Once the
sition, as levelling will eliminate rocking or excessive noise when the fan is in operation. Once the appliance is level,
appliance is level, move it partially into place to allow for all connections to be made. It is not practical to level the
move it partially into place to allow for all connections to be made. It is not practical to level the appliance once it
appliance once it has been installed. Determine the required depth prior to installing the appliance and adjust the
has been installed. Determine the required depth prior to installing the appliance and adjust the levelling screws
levelling screws accordingly.
accordingly.
2.0 installation planning
installation planning
WARNING:
THIS FIREPLACE HAS BEEN CONVERTED FOR USE WITH A GAS FIREPLACE
INSERT ONLY AND CANNOT BE USED FOR BURNING WOOD OR SOLID FUELS UNLESS ALL ORIGINAL
PARTS HAVE BEEN REPLACED AND THE FIREPLACE IS RE-APPROVED BY THE AUTHORITY HAVING
JURISDICTION.
W385-0199
ATTENTION:
CE FOYER A ETE CONVERTI AFIN D'ETRE UTILISE SEULEMENT
COMME FOYER ENCASTRE AU GAZ ET NE PEUT ETRE UTILSE POUR BRULER DU BOIS OU
TOUT AUTRE COMBUSTIBLE SOLIDE, SANS QUE TOUTES LES PIECES ORIGINALES AIENT
ETE REMPLACEES ET QUE LE FOYER SOIT APPROUVE DE NOUVEAU PAR LES AUTORITES
AYANT JURIDICTION.
ADVERTENCIA:
ESTA CHIMENEA SE REMODELÓ PARA USARSE SOLO CON UNA
INSERCIÓN DE CHIMENEA A GAS Y NO PUEDE USARSE PARA QUEMAR MADERA NI COMBUSTIBLES
SÓLIDOS, A MENOS QUE SE HAYAN REEMPLAZADO TODAS LAS PIEZAS ORIGINALES, Y LA AUTORI-
DAD JURISDICCIONAL LA HAYA VUELTO A APROBAR.
CLASS IIA-2 LABEL
2
/
" x 6"
/
2 HOLES 0.188" DIAMETER
1
2
C
W
BLACK LETTERING ON WHITE ALUMINUM
WARNING LETTERING TO BE NO LESS THAN 0.240"
OTHER LETTERING TO BE NO LESS THAN 0.120"
WOLF STEEL
TITLE:
FIREPLACE WARNING TAG - ULC S628
CDIZC / GDIZC
REVISION: A: 02.02.07 II ADD NOTE B: 01.15.08 II ADD SPANISH_RICH
41.1
EN
W385-0199_B
42.2
DIMS:INCHES
DWG #:
W385-0199
DATE:
07.25.00
11
W415-1802 / B / 02.07.19