Installation Planning; Minimum Clearance To Combustibles - Napoleon S25i Manuel D'installation Et D'opération

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Clean all ashes out of the inside of the existing fireplace opening. Make sure that the chimney and fireplace are free
of cracks, loose mortar, creosote deposits, blockage or other signs of deterioration. If necessary, have any repair
work done by a qualified professional before installing the insert.
Do NOT remove bricks or mortar from the fireplace. In case of an outside air inlet or ash dump, fill with fiberglass
insulation. Adhere to minimum clearances as illustrated.
Combustible material must not protrude more than 1" (25mm) to the side of the insert or between the mantel and
the top of the insert.
2.1

minimum clearance to combustibles

MINIMUM CLEARANCES
Sidewall
A
B
Mantel
Floor to bottom
of glass w/out
floor protection
C
Floor to bottom
of glass w/ floor
protection
D
Side trim to glass
Hearth (front)
E
Minimum hearth
F
extension
G
Hearth (side)
H
In front of insert
MINIMUM EXISTING
FIREPLACE DIMENSIONS
Width (rear)
I
J
Width (front)
Height (front)
K
L
Height (rear)
M Min. depth
Hearth width
N
O
Min. facing width
Min. facing height
P
Mantel
Q
* R value (with hearth floor protection of 19" depth):
1,471 in Canada
2,957 in U.S.A
20 1/2" (521mm)
30" (762mm)
17" (432mm)
6.5" (165mm) *
15" (381mm)
19" (483mm)
USA
(406mm)
Canada
(457mm)
8" (203mm)
48" (1219mm)
29" (737mm)
31" (787mm)
23 1/2" (597mm)
15 1/2" (394mm)
44 3/4" (1137mm)
SBP25I3348
(large backer plate)
(1219mm)
SBP25I3041
(standard backer plate)
(1041mm)
SBP25I3348
(large backer plate)
(838mm)
SBP25I3041
(standard backer plate)
(762mm)
53 1/2" (1359mm)

2.0 installation planning

16"
18"
48"
41"
33"
30"
EN
9
W415-2838 / A / 08.20.20