AVENTICS | Bus Coupler AES/Valve Driver AV, PROFIBUS DP | R412018135–BAL–001–AG
Fig. 5:
Address switches
The two rotary switches S1 and S2 for the station address of the valve system in the PROFIBUS DP
are located underneath the window (3).
S1
Switch S1: The tens digit of the address is set at switch S1. Switch S1 is labeled using the
hexadecimal system from 0 to F.
S2
Switch S2: The units digit of the address is set at switch S2. Switch S2 is labeled using the
decimal system from 0 to 9.
Proceed as follows during addressing.
1. Disconnect the bus coupler from the power supply UL.
2. Set the station address at the switches S1 and S2 (see Fig. 5):
– S1: tens digit from 0 to F
– S2: units digit from 0 to 9
3. Reconnect the power supply UL. The system will be initialized and the address applied to the bus
coupler.
S1
S2
S1
S2
and
on the bus coupler
Presettings on the Bus Coupler
S1
S2
3