1 - TECHNICAL SPECIFICATIONS

-
Power supply: ................................................................................................. N° 2 alkaline batteries 1.5 V type AA (LR6)
-
Autonomy: ...................................................................................................... approx. 3 years (display always on)
-
Time remaining from when "Battery Low" symbol appears
-
Control output: ............................................................................................... via radio (to an actuator receiver of the
-
Antenna: ......................................................................................................... built into the device
-
Radio emission
: .................................................................
-
Maximum signal range in a clear area: ......................................................... 1 0 metres
-
Maximum signal range in the presence of walls or obstacles: ..................... 30 metres (in accordance with chapter 4.4)
-
Software: ........................................................................................................ Class A
-
Input for telephone programmer: .................................................................. for a voltage free NO contact
Cross-section of wires to telephone programmer input terminals: .............. 0,5 mm ÷ 1,5 mm
-
-
Insulation type: .............................................................................................. Class III
-
Degree of protection: .................................................................................... IP 30
-
Pollution rating: ............................................................................................. normal
-
Type of installation: ....................................................................................... wall mounting (table base optional)
-
Room temperature display range: ............................................................... - 5°C ÷ +39°C
-
Ambient temperature indicator resolution: .................................................. 0,1°C
-
Set temperature setting adjustment field (t1/t2): ......................................... + 4°C ÷ +39°C (
-
Absence (t3) set temperature setting adjustment field: .............................. excludable or adjustable from + 4°C to + 39°C
Setting temperature resolution: .................................................................... 0,5°C
-
-
Room temperature detection correction (OFFSET): .................................... adjustable from -1.9°C to +1.9°C (default 0.0°C)
-
Differential ON/OFF temperature adjustment method: ................................ adjustable from 0.2°C to 0.7°C (default 0.3°C)
-
Energy classification: .................................................................................... ErP: Class I; 1% Reg. EU 811/2013
Thermal gradient: .......................................................................................... max 1°K / 15 min
-
-
Operating temperature limits: ....................................................................... -5°C ÷ +55°C
-
Storing temperature limits: ............................................................................ -10°C ÷ +65°C
When the room temperature blinks, display range (-5°C or 39 ÷ 39.9°C) has been exceeded.
Err indicates that heat control activity has been suspended due to probe error.
- ........................................................................................................................
: ...................... 30 days
"Wireless Temperature Control" family)
............................
. the device intentionally emits radio waves
on the frequency band of "868-868.6" MHZ,
with a maximum power of less than 25mW e.r.p
2
2
(in Winter mode = default 5°C - Summer = default 33°C)
2
restrictable
)
55