Alcove Enclosure; Non-Combustible Facing Material; Side View; Top View - Continental Fireplaces CLHD45N Instructions D'installation Et D'opération

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

30
5.2

ALCOVE ENCLOSURE

EN
NOTE: Recesses or alcoves above the appliance can be made as deep as desired provided the minimum
clearances to combustibles are maintained.
Non-combustible material can be used, provided the minimum clearances to combustible materials are applied.
The minimum enclosure volume must be increased by no less than the volume of the recess. This adjustment
can be made by increasing any or all of the height, width and depth of the enclosure.
5.3

NON-COMBUSTIBLE FACING MATERIAL

FINISH
MATERIAL
FRONT OF
APPLIANCE
WARNING: Non-combustible facing material must not protrude more than 3/4" (19mm) from the top,
and/or sides of the appliance. If it does, it is considered a non-combustible mantel and must meet the
non-combustible mantel clearance requirements.
W415-1336 / 08.21.14
RECESS OR
ALCOVE
AREA

SIDE VIEW

NON-COMBUSTIBLE
FACING MATERIAL
3/4" (19mm)
ENCLOSURE
AREA
APPLIANCE
FRONT OF
APPLIANCE
3/4" (19mm)
71.2
TOP VIEW
FINISH
MATERIAL
NON-COMBUSTIBLE
FACING MATERIAL
71.3A

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Clhd45p

Table des Matières