11.5 VALVE REMOVAL

Carefully lift the valve train assembly and turn off
A.
the manual shut-off valve, see "VALVE TRAIN
EN
ASSEMBLY" and "GAS INSTALLATION" section.
NOTE: A new gasket may be required, when
re-installing the valve train assembly, contact
your local Authorized dealer / distributor.
Disconnect the fl ex connector from the valve.
Remove the valve wire connections, labeling
each one to aid with re-connection.
Remove the four screws from the valve bracket
B.
and remove the valve.
Replace all components before returning the
C.
appliance to service.
Check for gas leaks by brushing on a soap and
D.
water solution.

11.6 RESTRICTING VERTICAL VENTS

Vertical terminations may display a very active fl ame. If this appearance is not desirable, the vent exit may be
restricted using restrictor supplied. This reduces the velocity of the exhaust gases, slowing down the fl ame
pattern and creating a more traditional appearance.
Line up the holes on the restrictor plate with the holes in the top of the fi rebox and secure.
A.
W415-1336 / 08.21.14
optional restictor
S T
R E
L
T E
N A
L A
T I O
R P
O P
T O
R I C
GASKET
VALVE
BRACKET
VALVE