Maintenance
▶ Allow the tank to cool down sufficiently before performing any
maintenance.
▶ Carry out cleaning and maintenance procedures in the specified
intervals.
▶ Remedy all faults immediately.
▶ Use original spare parts only!
▶ The tank must be inspected annually and maintained as required.
9.1
Testing relief valve
▶ Check the T&P safety valve annually.
9.1.1 Drain the tank
▶ Isolate the tank on the DHW side from the piping by closing the shut-
off valves.
▶ Open a high-level tap to vent the system.
▶ Open drain valve ( Fig. 2 [12], page 6).
14
9.1.2 Descaling/cleaning the tank
▶ Close the cold water inlet shutoff valve.
▶ Drain the tank via the drain valve by opening the highest faucet.
▶ Check the tank interior for contamination (lime scale deposits,
sediment).
In order to improve the cleaning effect, heat up the
indirect coil prior to hosing them down with a water jet.
The thermal shock effect helps to loosen encrustations
(e. g. lime deposits).
NOTICE: Damage to the enamel finish!
▶ Do not use tools for the removal of deposits from the
interior of the tank as it may damage the enamel liner.
▶ Hose down the inside of the tank.
72 Psi (5 bar)
50 °F (10 °C)
Fig. 14 Hosing down the inside of the tank
▶ Use a wet & dry vacuum cleaner with plastic suction hose to remove
the residues.
▶ Seal the plug back into the inspection port.