INSTALLATION 
 
Approved Venting Method 1: Through the Wall 
clearances to combustibles. 
 Use an appliance collar where the pellet vent connects to the exhaust output of the pellet 
stove and attach the appliance collar to the exhaust blower output using three sheet metal 
screws.  
 Secure the pellet vent to the outside of the house using a wall strap just below the 90 
degree elbow. 
 Seal each pipe connection joint with high temperature RTV Silicone, to ensure the system is 
leak free (Check with the specific venting system manufacturer's instructions before doing 
so). 
 If the pellet vent pipe being used is not a "Twist Lock" system, three (3) sheet metal screws 
are required at each pipe joint. 
 Connect the pellet stove to outside combustion air using the kit included with your stove or 
using an alternative method, as described in the "Outside Air" section, on page 15. 
 This installation type can be modified for basement (Basement installations should always 
be performed by a professional installer) or other installations wherein the tee and vertical 
section of the pipe would be inside the home and the venting system would simply pass 
horizontally through the thimble and then terminate. 
Please Note: Installation diagrams are for reference purposes only and are not drawn to scale, nor
meant to be used as plans for each individual installation. Please follow all venting system
requirements, maintain the required clearances to combustibles, and follow all local codes.
IMPORTANT! READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING
CLEANING THE UNIT AS SPECIFIED, AND REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED.
ENGLAND'S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT, OR
DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH QUESTIONS.
For high altitude installations (above 4,000
ft.), the vent pipe should be increased from
 
 Generally the simplest installation method, 
venting through the wall using our AC‐3000 
kit, AC‐33000 if Canada (or similar venting 
system) is also the preferred venting 
method.  It minimizes horizontal pipe, 
allows the stove to be installed close to the 
wall and keeps the clean‐out tee on the 
outside of the house, for ease of cleaning. 
 When installing any venting system, Type L 
or Type PL pipe must be used and all 
clearances to combustibles (listed by the 
pipe manufacturer) must be strictly 
adhered to. 
 Use the pipe manufacturer's approved 
thimble for passing through a combustible 
wall, and maintain at least the minimum 
11
3-inch (3") to four-inch (4").