INSTALLATION
Approved Venting Method 1: Through the Wall
sheet metal screws.
Secure the pellet vent to the outside of the house using a wall strap just below the 90 degree
elbow.
Seal each pipe connection joint with high temperature RTV Silicone, to ensure the system is leak
free (Check with the specific venting system manufacturer's instructions before doing so).
If the pellet vent pipe being used is not a "Twist Lock" system, three (3) sheet metal screws are
required at each pipe joint.
Connect the pellet stove to outside combustion air using the kit included with your stove or using
an alternative method, as described in the "Outside Air" section, on page 16.
This installation type can be modified for basement (Basement installations should always be
performed by a professional installer) or other installations wherein the tee and vertical section of
the pipe would be inside the home and the venting system would simply pass horizontally through
the thimble and then terminate.
Please Note:
Installation diagrams are for reference purposes only and are not drawn to scale, nor meant to be used as plans for each
individual installation. Please follow all venting system requirements, maintain the required clearances to combustibles,
and follow all local codes.
IMPORTANT! READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING CLEANING THE UNIT AS SPECIFIED, AND
ENGLAND'S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT, OR DUE TO UNSAFE INSTALLATION OR
Generally the simplest installation method, venting
through the wall using our AC‐3000 kit, AC‐33000 if Canada
(or similar venting system) is also the preferred venting
method. It minimizes horizontal pipe, allows the stove to
be installed close to the wall and keeps the clean‐out tee
on the outside of the house, for ease of cleaning.
When installing any venting system, Type L or Type PL
pipe must be used and all clearances to combustibles
(listed by the pipe manufacturer) must be strictly adhered
to.
Use the pipe manufacturer's approved thimble for
passing through a combustible wall, and maintain at least
the minimum clearances to combustibles.
Use an appliance collar where the pellet vent connects
to the exhaust output of the pellet stove and attach the
appliance collar to the exhaust blower output using three
REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED.
USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH ANY QUESTIONS.
For high altitude installations
(above 4,000 ft.), the vent pipe
should be increased from 3‐inch
(3") to four‐inch (4").
11