IMPROPER GASKET MAINTENANCE, INCLUDING FAILURE TO REPLACE
GASKETS, CAN CAUSE AIR LEAKS RESULTING IN SMOKE-BACKS.
Gaskets
1. Door
o This unit comes with a
annually. To replace the door gasket (Part # AC‐DGKNC), the old gasket must first
be removed entirely — prior to adding the new adhesive, you may have to
scrape the old cement from the door channel. Once the cement and gasket have
been added, the door should be closed and latched for twenty‐four hours to
allow the cement to harden.
2. Window
o If you are replacing the window gasket (Part # AC‐GGK), the new gasket will
already have adhesive on one side. Remove the paper on the adhesive side and
place the gasket around the outside edge of the glass, centered over the edge.
Fold the gasket edges over on the glass, forming a "U" shape.
3. Combustion Blower
o The Combustion Blower Gasket (Part # PU‐CBG) should be inspected whenever
you remove or clean the Combustion Blower and replaced if necessary.
4. Combustion Blower Motor
o The combustion blower motor gasket (Part # PU‐CMG) generally does not need
replacement, as it not normally removed from the unit. However, if the exhaust
blower is cleaned by removing the motor, rather than the entire blower
assembly, this gasket must be inspected and replaced as necessary.
5. In addition, the Hopper Lid gasket and Ash Pan gasket should be inspected and replaced
annually, or sooner if necessary (see "Checking Gaskets" in the Yearly Maintenance
section).
Finish
This new unit has been painted with High‐Temperature Paint that should retain its
original look for years. If the unit should get wet and rust spots appear, the spots can be sanded
with fine steel wool and repainted. It is crucial that only High‐Temperature Spray Paint is used
(Part # AC‐MBSP), as others may not adhere to the surface or withstand the high temperatures.
Similarly, some brands of paint will not adhere to different brands of paint, so we highly
recommend using our proprietary High‐Temperature Spray Paint.
IMPORTANT! READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING
CLEANING THE UNIT AS SPECIFIED, AND REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED.
ENGLAND'S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT, OR
DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH QUESTIONS.
REPLACING COMPONENTS
5
/
" rope gasket around the door that should be replaced