Approved Venting Method 2: Through the Ceiling
Storm Collar
Roof Flashing
Ceiling Support Box
•
Prefabricated chimney systems must conform to UL‐103HT (2100 °F) for the U.S. and ULC‐S629 (650°C) for
Canada.
•
This wood burning unit is only listed for installation with 6.0" diameter chimney connector and chimney systems.
Installing this unit on prefabricated chimneys larger than 6.0" diameter will result in decreased draft and the potential for
poor unit performance.
•
Follow all venting system manufacturer's installation requirements and required clearances.
•
Use three sheet metal screws at each single wall chimney connector joint (check manufacturer's
recommendations when double wall chimney connector is used).
•
Drill three holes in the flue collar of the unit and attach the chimney connector to the unit using sheet metal screws
(holes should be pre‐drilled in flue collar from factory).
•
Properly attach the prefabricated chimney system to the home in strict accordance with the prefabricated chimney
system manufacturer's instructions.
•
The overall length of the chimney connector must not exceed 8.0 ft. In the case of cathedral ceilings, the
prefabricated chimney system should extend to 8.0 ft. from the top of the unit if using single wall chimney
connector pipe. If necessary to run longer than 8.0 ft. of chimney connector pipe, double wall black chimney
connector pipe must be used.
•
Special adapters and slip connectors are available to eliminate the need to cut single wall chimney connector.
Double wall chimney connector must be used with these slip connectors, as it cannot be trimmed to length.
Please Note: Installation diagrams are for reference purposes only and are not drawn to scale, nor meant to be used as plans
for each individual installation. Please follow all venting system requirements, maintain the required clearances to
combustibles, and follow all local codes
Page | 12
INSTALLATION
10 ft.
Termination Cap
The 10‐3‐2 Rule: The chimney system
must terminate 3.0 ft. above the point
where its centerline passes through the
roof AND the chimney must terminate
2.0 ft. above any part of the dwelling
within a 10 ft. radius of the chimney.
Class A Chimney System
Chimney Connector
(Single or Double Wall)