INSTALLATION
Approved Venting Method 2: Through the Ceiling
and attach the appliance collar to the exhaust blower output using three sheet metal
screws.
Seal each pipe connection joint with high temperature RTV Silicone, to ensure the system is
leak free (Check with the specific pipe manufacturer's instructions before doing so).
If the pellet vent pipe being used is not a "Twist Lock" system, three (3) sheet metal screws
are required at each pipe joint.
Connect the pellet stove to outside combustion air using the kit included with your stove or
using an alternative method, as described in the "Outside Air" section, on page 15.
This venting method can also be modified so that the venting system runs horizontally
through the wall from the stove, then transitions to vertical and terminates above the
roofline. When using this modified version of this installation be certain to carefully follow
the venting system manufacturer's instructions diligently.
Please Note: Installation diagrams are for reference purposes only and are not drawn to scale, nor
meant to be used as plans for each individual installation. Please follow all venting system
requirements, maintain the required clearances to combustibles, and follow all local codes.
IMPORTANT! READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING
CLEANING THE UNIT AS SPECIFIED, AND REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED.
ENGLAND'S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT, OR
DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH QUESTIONS.
Venting through the ceiling/roof may be the only
feasible venting option in some cases and is a factory
recommended installation.
When installing any venting system, Type L or Type
PL pipe must be used and all clearances to
combustibles listed by the pipe manufacturer must
be strictly adhered to.
Use the pipe manufacturer's approved ceiling
support for passing through a combustible ceiling, as
well as the required firestops, radiation shields,
flashing and storm collar.
Be certain to follow the manufacturer's required
height of termination above the roof line, and
maintain at least the minimum clearances to
combustibles.
Use an appliance collar where the pellet vent
connects to the exhaust output of the pellet stove
12
For high altitude installations (above 4,000
ft.), the vent pipe should be increased from
3-inch (3") to four-inch (4").