8.3
n
8.4
8.4.1
c
w
0313851_DRE_NLUKFR, 30-03-2022

Installation diagram

Fig. Installation diagram
14
14 14
11
12
T
B
9
Note
Use this installation diagram when you:
-
install the water connections (see 8.4)
-
fill the water heater (see 8.6.1)
-
drain the water heater

Water connections

Cold water connection

Caution
When installing the heater, you need an expansion valve. The expansion valve and
associated fittings are not included in the package. The expansion valve must be suitable
for a water pressure level of up to 800 kPa. Install the expansion vessel and expansion
valve as close as possible to the water heater.
Warning
Never install a stop valve or a non-return valve between the expansion vessel/expansion
valve and the water heater.
Warning
The heater is intended to be connected to the water mains permanently. Do not use a
hose set to connect the heater.
1. Pressure reducing valve
3. T&P valve (mandatory)
4. Stop valve (recommended)
5. Non-return valve
6. Circulation pump (optional)
9. Drain valve
3
11. Service stop valve
4
6
12. Temperature gauge (optional)
5
14. Draw-off point
4
15. Expansion valve
16. Expansion vessel
A. Cold water supply
C
B. Hot water outlet
C. Circulation pipe
16
5
1
4
A
15
(mandatory if the mains water
pressure is too high)